Subfunction 23. Device X -ON/X -OFF Characters.
Data block
byte 0: character for device X -ON function
1: character for device X -OFF function
Validation: Two bytes must be given.
Subfunction 24. Host ENQ/ ACK Characters.
Data block
byte 0: character for host ENQ function
1: character for host ACK function
Validation: Two bytes must be given.
Subfunction 25. Host ENQ/ ACK Pacing Counter.
Data block
HP 27130A
byte 0:
the number of characters to transmit before sending an ENQ and waiting for
an ACK (count should be 1 to 255)
Validation: One byte must be given.
Subfunction 27. Single Text Terminator for Echoing CR-LF. Anyone of the single text terminator
characters may be specified to cause the echoing of the CR:-LF characters.
However, only one
character may be used for the special echoing function.
This character is specified in the data
block for this subfunction.
Validation: none
Subfunction 28. Output Separator.
Data block
byte 0: lst output separator character or null
1: 2nd output separator character or null
Validation: Length must be one or two characters.