B-3
CARBURETOR
USAGE INSTRUCTIONS FOR SEA-
SONAL CHANGE OVER
WARNING
ELECTRIC SHOCK can kill.
• Do not operate with panels open.
• Disconnect NEGATIVE(-) BATTERY
LEAD before servicing.
• Do not touch electrically live parts.
------------------------------------------------------------------------
MOVING PARTS can injure.
• Keep guards in place.
• Keep away from moving parts.
• Only qualified personnel should
install, use or service this equipment.
------------------------------------------------------------------------
The engine MUST BE COLD before seasonal
change over of the carburetor deicing kit.
When the AVERAGE AIR INTAKE TEMPERATURE
(Average Ambient) is:
Below 60°F / 15.5°C (Winter Season
Configuration)
1. With the engine OFF, remove the negative cable
from the battery.
2. Push the FLEXIBLE HOSE fully onto the HEAT
COLLECTOR SHIELD outlet tube, see Figure 1.
3. Reconnect negative battery cable.
FIGURE 1
B
A
A. FUEL TANK
B. HEAT COLLECTOR SHIELD
OPERATION
DEICING
KIT
E
D
C
CLASSIC I
C. FLEXIBLE HOSE
D. GEAR CLAMP
E. AIR FILTER
Above 60°F / 15.5°C (Summer Season
Configuration)
1. With the engine OFF, remove the negative cable
from the battery.
2. Remove the FLEXIBLE HOSE from the HEAT
COLLECTOR SHIELD outlet tube.
3. The FLEXIBLE HOSE is to be positioned per fig-
ure 2.
IMPORTANT: 1/2" clearance between the FLEXI-
BLE HOSE and the fuel tank edge is required.
Also 2" clearance between FLEXIBLE HOSE and
roof.
4.Reconnect negative battery cable.
FIGURE 2
B
A
A. FLEXIBLE HOSE
B. HEAT COLLECTOR SHIELD
C. AIR FILTER
NOTE: On welders received directly from the factory,
the "Deicing" kit is configured for "summer Seasons"
B-3