CHARGING THE bATTERY

When you charge, jump, replace, or otherwise connect
battery cables to the battery, be sure the polarity is
correct. Improper polarity can damage the charging
circuit. The AIR VANTAGE® 500 (AU) positive (+) bat-
tery terminal has a red terminal cover.
If you need to charge the battery with an external
charger, disconnect the negative cable first, then the
positive cable before you attach the charger leads.
after the battery is charged, reconnect the positive bat-
tery cable first and the negative cable last. Failure to
do so can result in damage to the internal charger
components.
Follow the instructions of the battery charger manufac-
turer for proper charger settings and charging time.
NAMEPLATES / WARNING DECALS MAIN-
TENANCE
Whenever routine maintenance is performed on this
machine - or at least yearly - inspect all nameplates
and labels for legibility. Replace those which are no
longer clear. Refer to the parts list for the replacement
item number.
ITEM
Air Cleaner Element
Oil Filer
Fan Belt
Fuel Strainer
Fuel Filter /
Water Separator
Battery
Engine Oil Change
MAINTENANCE
Table D.1 Engine Maintenance Components
MAKE
PART NUMbER
Donaldson
P822768
Fleetguard
AF25436
Cummins
C6002112110
Fleetguard
LF16011
Cummins
C0412021749
Cummins
3826094
Fleetguard
FF5079
Fleetguard
FS19594
-----
BCI GROUP 34
See Manual
-----
AIR VANTAGE® 500 (AU)
WELDER / GENERATOR MAINTE-
NANCE
STORAGE
Store the AIR VANTAGE® 500 (AU) in a clean, dry
protected areas.
CLEANING
Blow out the generator and controls periodically with
low pressure air. Do this at least once a week in par-
ticularly dirty areas.
bRUSH REMOVAL AND REPLACEMENT
It is normal for the brushes and slip rings to wear and
darken slightly. Inspect the brushes when a generator
overhaul is necessary.
WARNING
Do not attempt to polish slip rings while the
engine is running.
------------------------------------------------------------------------
SERVICE INTERVAL
Replace as indicated by
Service Indicator
Replace every 750 hours or 3 months,
whichever is less.
Inspect every 1000 hours or 12 months,
whichever is less.
Inspect and replace monthly as
required. Replace annually.
Replace every 500 hours or 6 months,
whichever is less.
Inspect every 500 hours
Change every 750 hours or 3 months,
whichever is less. Check daily.
D-4