jetek pro jts-322dn User Manual

Economic intelligent high speed dome

Advertisement

Quick Links

Economic Intelligent
High Speed Dome
User's Manual
1

Advertisement

Table of Contents
loading

Summary of Contents for jetek pro jts-322dn

  • Page 1 Economic Intelligent High Speed Dome User’s Manual...
  • Page 2: Table Of Contents

    C O N T E N T S GENERAL ITRODUCTION ........................  3  .......................  5 MPORTANT  AFETY  NSTRUCTIONS CHAPTER 1        INTRODUCTION.......................  5  ...........................  5   NTRODUCTION  ............................  5   ICTURES   ............................  6   EATURES  ..........................  7   ECHNICAL  CHAPTER 2    INSTALLATION AND CONNECTION ................  9  ...................... ...
  • Page 3: General Itroduction

    GENERAL ITRODUCTION Notice Do not dismantle the machine to avoid electric shock Notice: To avoid electric shock, do not remove the dome cover. Users are not capable of fixing any internal components. Only qualified personnel are allowed to do the maintenance. This label indicates risk of electric shock inside the dome.。...
  • Page 4 Do not install the unit in humid, dusty or smoky places may cause fire or electric shock. This could avoid fire, electric shock or personal injury caused by falling objects. If the device has abnormal smell or smoke, please stop using the product. You should immediately unplug the power and service center.
  • Page 5: Important Safety Instructions

    Important Safety Instructions Please read before using these instructions and follow all instructions and pay attention to all warnings。 Please do not run the machine near water。 Please clean the machine with a dry cloth。 Do not block ventilation openings, and while installing, please note the manufacturer's instructions。...
  • Page 6: Features

    1.3 Features OSD Menu Support Chinese and English OSD menu, and can display the speed dome information and status, also can setup speed dome functions and features. Soft Address Support soft address function. Soft address can be set in OSD menu, and speed dome can be controlled by keyboard and PC software with different soft address.
  • Page 7: Technical Data

    After start this function, it can set password, Lens Control Zoom control and focus control 1.4 Technical Data 1.4.1 Technical Parameters of the High-speed Dome Model JTS-322DN High Speed Dome Camera AC24V/2.5A Power Supply -35 °C—60°C Operating Temperature < 95%...
  • Page 8 IP66 water proof/3000V lightning proof Protection Fan and heater auto-starts 24VAC Fan, Heater 1.4.2 Camera Parameter for High-speed Dome JTS-322DN Sub Model 1/4’’ Sony Super HAD CCD Sensor 540TVL Horizontal Resolution F=4mm-88mm Focus Length Optical Zoom Digital Zoom 0.11Lux/0.011Lux Minimum Illumination...
  • Page 9: Chapter 2 Installation And Connection

    Chapter 2 Installation and Connection 2.1 Optional parts for installation Pedant mount bracket for pedant mounting Pedant mount bracket(TC-DF12)for ceiling mounting 2.2 Warning Select place which can afford four times weight more that speed dome. Prevent others closely to avoid causing injuries while installation. Move other precious away before installation.
  • Page 10: Installation

    2.4 Installation 1. Get the foam out of the carton Note: Please protect camera and dome base, make sure the foam is removed from the carton vertically and slowly, otherwise may lead to damage on camera. Please refer to chapter 2.5<Initial Settings> for Dip Switch Settings 2、...
  • Page 11 As is shown by the picture, thread the power cable, video cable,RS-485data cable 4、 through the bracket, push speed dome into bracket connection, and tighten 3 internal hexagon screws 5、Cable connection 6. Put the cables (including power, video cable, RS 485 and ground line) through the bracket. Then fix the dome base and the bracket with 4 screws and lock with ¢8 plain cushion and nut.
  • Page 12 Size of wall mount: Size of in-ceiling mount: Note: The thickness of ceiling should be between 4.2cm to 0.8cm.And the ceiling should support 20kg within 225mm diameter.
  • Page 13: Setting

    2.5 Setting Dome Address Use SW1 to set dome address. Dome setting adopts binary system, the 8th bit is the highest, the 1st bit is the lowest. Total 255 dome addresses could be set. Note: 1、 Put the dial to “ON”, and “1” means “on” status and “0” means “off” status. 2、...
  • Page 14 Baud Rate 4bit 5bit 9600bps 4800bps 2400bps Preset 4、 Dome address code table under protocol TIANDY/PELCO-P: Address PIN1 PIN2 PIN3 PIN4 PIN5 PIN6 PIN7 PIN8...
  • Page 15 … … … … … … … … … Comparison chart of the PELCO-D protocol address. Address PIN1 PIN2 PIN3 PIN4 PIN5 PIN6 PIN7 PIN8...
  • Page 16 … … … … … … … … …...
  • Page 17: Chapter 3 Settings

    Chapter 3 Settings Connect the camera to the control device or control software. control device, including controlling keyboards and hard disk recorders, and control software, which designed for the clients, can be used to change camera settings. See also the user manual to grasp the specific operations.
  • Page 18 SYSTEM INFORMATION ―――――――――――――― DOME ID : 0 1 2 3 4 5 6 7 8 9 ADDRESS : 0 0 1 BAUDRATE : 9600,N,8,1 PROTOCOL : TIANDY TEMP : 31℃ ALARM : 000000 00 <OTHER> BACK EXIT DISPLAY ―――――――――――――― DOME :OFF PRESET :OFF...
  • Page 19: Motion

    3.4 MOTION MAIN MENU MOTION ―――――――――――――― ―――――――――――――― <PRESET> LANGUAGE: ENGLISH <SCAN> <SYSTEM INFORMATION> <SEQUENCE> <DISPLAY SETUP> <PATTERN> <DOME SETTINGS> <ZONES> <CAMERA> <TIMING ACTION> <MOTION> <AUTO TRACKING> RESTART FACTORY DEFAULTS BACK EXIT HELP EXIT A. PRESET PRESET MOTION ―――――――――――――― ―――――――――――――― ―――――――――――――― PRESET NO.
  • Page 20 B1. TITLE Move the cursor to TITLE and press IRIS ON to enter the edition mode of preset title. C1.CALL MOVE the cursor to CALL and press IRIS ON to call upon the current preset position. D1.SET Move the cursor to SET and press IRIS ON the enter preset setting mode. Then the sentence “PRESS IRIS ON TO CONFIRM”will appear on the screen.
  • Page 21 C1.START MOVE the cursor to START and press IRIS ON to start the current scan. D1.<LEFT LIMIT> Move the cursor to <LEFT LIMIT> and press IRIS ON to start setting the left limit of the current scan. Then the sentence “PRESS IRIS ON TO CONFIRM” will appear on the screen. Move the joystick and press IRIS ON to confirm.
  • Page 22 C1.START MOVE the cursor to START and press IRIS ON to start the current sequence. D1.<SEQUENCE SET> Press IRIS ON to enter into the sequence setting SEQUENCE SEQUENCE ―――――――――――――― ―――――――――――――― SEQ NO. : 1 PRESET INTERVAL TITLE : SEQ 1 0 0 2 >>...
  • Page 23 MOTION PATTERN ―――――――――――――― ―――――――――――――― <PRESET> PATTERN NO. : 1 <SCAN> TITLE : PATTERN 1 <SEQUENCE> START <PATTERN> <SET> <ZONES> DELETE <TIMING ACTION> <AUTO TRACKING> BACK BACK EXIT EXIT A1.PATTERN NO. Move the cursor to PATT and press the key IRIS ON(key on control keyboard) to enter the edition mode of sequence No., move the joystick upward and downward to select number.
  • Page 24 MOTION ZONES ―――――――――――――― ―――――――――――――― <PRESET> ZONE IS NOT SET - - <SCAN> ZONE NO. : 1 <SEQUENCE> TITLE NO. : ZONE 1 <PATTERN> <LEFT LIMIT> <ZONES> <RIGHT LIMIT> <TIMING ACTION> DELETE <AUTO TRACKING> BACK BACK EXIT EXIT A1.ZONE INFORMATION B1.ZONE NO. Move the cursor to ZONE NO.
  • Page 25 MOTION TIMING ACTION ―――――――――――――― ―――――――――――――― <PRESET> START STOP MOTION <SCAN> 0 0 : 0 0 0 0 : 0 0 NONE <SEQUENCE> NONE 0 0 : 0 0 0 0 : 0 0 <PATTERN> NONE 0 0 : 0 0 0 0 : 0 0 <ZONES>...
  • Page 26: Dome Setting

    MOTION AUTO TRACKING ―――――――――――――― ―――――――――――――― <PRESET> <SCAN> SENSITIVITY : 06 <SEQUENCE> FRAME RATE: MID <PATTERN> ENABLE: OFF <ZONES> <TIMING ACTION> <AUTO TRACKING> BACK EXIT A1.SENSITIVITY Secitivity of auto tracking funtion. Scale from1 to 15. B1.FRAME RATE Setting of the frame inspection rate. C1.ENABLE Enabel or disable the auto tracking function.
  • Page 27 IDLE ACTION DOME SETTINGS ―――――――――――――― ―――――――――――――― <IDLE> TIME 3 0 SEC <ALARM> ACTION : NO ACTION <AUX> <PRIVACY MASK> <CLOCK> <PASSWORD> <DOME TITLE> <OTHERS> BACK EXIT BACK EXIT A1:IDLE ACTION Move the cursor to TIME, press IRIS ON to enter the edition mode of idle action starting time. The time could be 30seconds, 2 minutes, 5 minutes or 10 minutes.
  • Page 28 Then the sentence “PRESS IRIS ON TO CONFIRM” will be displayed on the monitor. Use joystick to move the dome to the area you want to cover and press IRIS ON to confirm. There will be a privacy zone in the middle of the monitor. Move joystick upward, downward, leftward and rightward to adjust the size of privacy zone.
  • Page 29 Move the cursor to INPUT and press IRIS ON to enter the title edition mode. B1. Move the cursor to CAPS. Press IRIS ON and move the joystick upward and downward to select capital and small letters. C1. ALPHABET Move the cursor to alphabet and press IRIS ON to select letters. H.
  • Page 30: Camera

    F1. <NORTH SET> Move to cursor to NOTTH SET and press IRIS ON to set the direction null point. 3.6 CAMERA MAIN MENU CAMERA SETTING ―――――――――――――― ―――――――――――――― AUTO FOCUS : OFF LANGUAGE: ENGLISH DIGITAL ZOOM : OFF <SYSTEM INFORMATION> BACKLIGHT : OFF <DISPLAY SETUP>...
  • Page 31: Working Setup

    C1. BLUE GAIN D1.BRIGHT E1.EXPOSURE F1.WIDE DYNAMIC *NOTICE: This item is only for the camera module with WDR function. 3.7 Working Setup...
  • Page 32: Preset Position

    Preset Position A: Preset Position Number 1-64, 100-255。 Move the cursor onto “Number of Preset Position”, press the icon “Iris on” to enter the preset position setting mode, use the stick to set preset positions. The dome cameras have 220 preset positions.
  • Page 33 A1.SCAN NO. Move the cursor to SCAN NO. and press the key IRIS ON(key on control keyboard) to enter the edition mode of scan No., move the joystick upward and downward to select number. Then press IRIS ON to confirm. The dome total support 8 groups scan. B1.
  • Page 34 SEQUENCE A1.SEQ NO. Move the cursor to SEQ NO. and press the key IRIS ON(key on control keyboard) to enter the edition mode of sequence No., move the joystick upward and downward to select number. Then press IRIS ON to confirm. B1.
  • Page 35 Move the cursor to EDIT and press IRIS ON to enter edition mode. Move the joystick rightward and leftward to select item. a. When the < > is on the item NO., move joystick upward and downward to select the NO.of the preset in a sequence.
  • Page 36 and press IRIS ON to confirm. E1.DELETE Move the cursor to DELETE and press IRIS ON to delete the current pattern. ZONE A1.ZONE INFORMATION B1.ZONE NO. Move the cursor to ZONE NO. and press the key IRIS ON(key on control keyboard) to enter the edition mode of zone No., move the joystick upward and downward to select number.
  • Page 37: Restart

    F1.DELETE Press IRIS ON to delete the current zone. 3.8 RESTART Press IRIS ON to restart the speed dome camera, to achieve the restart operation by remote control. 3.9 FACTORY DEFAULTS Press IRIS ON to restore all the settings into the factory default.
  • Page 38: Help And Exit

    3.10 Help and Exit Click Iris on to get the help information of shortcut. Move the cursor to the “Exit”, click iris on to exit the menu. Remark: 1: The camera block, such as Sony, Hitachi, Sanyo has OSD themselves. When operating its own OSD, please click the “Exit”...
  • Page 39: Appendix

    Appendix Appendix 1:Lightning and surge protection The outdoor speed dome need to have the function of lightning and surge protection, so that to make sure the electronic component is safe, you can take the following measures: The transmission cable must be keep 50 meters away from the high-tension apparatus and high-voltage cable;...
  • Page 40 When the cable is thin or EMI is strong or the there are too many other devices, the transmission distance will be shorten. 3. Connection and terminal resistance When arranging the wires, the way of connection use the way of snakelike, both of the ends must connect 120Ω...
  • Page 41 Picture 4 RS485 common faults solution Phenomenon Possible reason Solution 1、Host machine, speed dome’s address 1、Change the host machine, speed dome’s address and baud rate is not matching and baud rate to be the same Speed dome take self-checking, but can’t be 2、RS485’s+、- pole is reversed 2、Conversion the +、- pole controlled...

Table of Contents