CS-PW9DKE / CU-PW9DKE / CS-PW12DKE / CU-PW12DKE
9.2.5.
CONNECT THE CABLE TO THE
INDOOR UNIT
1. The inside and outside connecting cable can be connected
without removing the front grille.
2. Connecting cable between indoor unit and outdoor unit
shall
be
approved
(PW9DKE,PW12DKE) x 1.5 mm
designation 245 IEC 57 or heavier cord.
ı ı ı ı ˇ ı ˇ ı ˇ ı
ˇ ı E nsure the color of wires of outdoor unit and the
terminal Nos. are the same to the indoor's respectively.
ı ı ı ı ˇ ı ˇ ı ˇ ı
ˇ ı E arth lead wire shall be longer than the other lead wires
as shown in the figure for the electrical safety in case of
the slipping out of the cord from the anchorage.
Terminals on the indoor unit
Color of wires
Terminals on the outdoor unit
ı ı ı ı ˇ ı ˇ ı ˇ ı
ˇ ı S ecure the cable onto the control board with the holder
(clamper).
- 34 -
polychloroprene
sheathed
2
flexible cord, type
1(L) 2(N)
3
4
1(L) 2(N)
3
4
1
(L)
2
(N)
3
4
5
Connector