Installthe IndoorUnit
Hook the indoor unit onto the
upper portion of installation plate
(Engage the indoor unit with the
upper edge of the installation
plate). Ensure the hooks are
properly seated on the installation
plate by moving in left and right.
Indoor unit
Secure the IndoorUnit
1. Tape the extra power supply cord in a
bundle and keep it behind the chassis .
Ensure t hat the p ower s upply c ord is
not clamped in between the unit's hook
(2 positions) and installation plate.
2. Press the lower left and right side of the
unit against the installation plate until
hooks engages with their slots
(sound click).
Slee ve for
piping hole
Drain
hose
Piping
More than approx. 95 cm
Hooks at
installation
plate
Slee ve for
piping hole
Piping
Drain hose
Unit's
hook
Installation
plate
Connecting cable
Drain hose
Adjust the piping slightly downwards.