Installation Location - Sanden GAUS-315EQTD Installation Manual

Heat pump water heater with natural refrigerant (co2)
Hide thumbs Also See for GAUS-315EQTD:
Table of Contents

Advertisement

Installation location

For the most efficient operation of the heat pump unit the optimum location is the
warmest side of the property and there should be sufficient space for the air to circulate
through the unit.
The tank unit should be located as close as possible to the most frequently used hot
water outlet such as a bathroom. It may be located either outside or inside. The heat
pump unit must be located outside and as close as practicable to the tank unit but not
further than 50ft (15m) away from the tank.
Ensure sufficient clearance around the heat pump unit to allow air to circulate and
provide adequate space for service maintenance of the unit (Figure 3).
Although the heat pump unit is very quiet, it is preferable to avoid installing it directly
below a bedroom window.
Install the heat pump unit in an area which allows sufficient ventilation. Poor ventilation
may cause the unit to short cycle and this could increase power consumption by more
than 10%.
Do not install the heat pump unit in a confined space.
If the heat pump unit is installed facing a wall, exhaust air may stain the wall.
Figure 3: Restrictions on where the heat pump unit can be installed (overhead view)
>4" or
100mm
clearanc
e
Unit should have a minimum of 36" or 1000mm space above the unit to ensure correct operation
Discharge Air blowing against a wall/obstacle in front of the unit may stain the wall/obstacle
If the unit is not able to operate with adequate airflow due to obstacles and reduced clearances, then
heating output will be reduced by approx. 10% and power consumption increased by approx.10%
For optimum operation install the unit per the above or in a location with no obstacles
>4" or 100mm clearance
>4" or 100mm clearance
>12" or
300mm
clearance
Sanden Heat Pump – Installation Manual
Page 5 of 33
>4" or 100mm clearance
>8" or 200mm clearance

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gaus-315eqte

Table of Contents