PATENTS This water heater may be protected by one or more patents or registered designs in the name of Sanden Australia Pty. Ltd. TRADE MARKS ® Registered trademark of Sanden Australia Pty. Ltd. Note: Every care has been taken to ensure accuracy in preparation of this publication.
Introduction The Sanden Heat Pump Water Heater System has been designed using the latest refrigeration technology to remove the heat from the air to heat water. The refrigerant we use is CO which does not contribute to global warming so it allows us to help keep a clean healthy earth for future generations.
Page 6
Check the installation conditions of the unit. Installation of the unit in the following places could result in accidents or failure and the performance of the unit not being guaranteed. ∙ Anywhere the lowest temperature reached is under minus 10 degrees centigrade ∙ Indoors (Applies only to the heat pump unit) ∙ Anywhere not completely flat, unstable or where drainage is difficult ∙ Ensure not to put anything around the heat pump unit. Could result in poor performance and unexpected problems. In the winter in particular please pay attention to any snow coverage. Sanden Heat Pump – Owner’s Manual Page 6 of 16 ...
The unit must be stored and transported in an upright position. Failure to do so may render the unit faulty. Such failure is not covered under any warranty agreements. Failure to comply with the above conditions will void the warranty. Typical installation layout Sanden Heat Pump – Owner’s Manual Page 7 of 16 ...
If the system is equipped with freeze protect heaters, also do not shut the power supply to the heaters. Failure to do so may cause a crack on the pipes due to the pipes getting frozen. Sanden Heat Pump – Owner’s Manual Page 8 of 16 ...
Supply the power to the Heat Pump Unit and leave the water tap open for 3 minutes. Close the tap after no air is confirmed in the water. Caution Hot water may come out. Be careful not to get the hands burnt. Sanden Heat Pump – Owner’s Manual Page 9 of 16 ...
Select the electrical supply mode that best suits the customer’s hot water consumption. The type of off-peak connection may need to be changed if hot water supply is not maintained as required. Outline of electrical system connections Sanden Heat Pump – Owner’s Manual Page 10 of 16 ...
Dimensions and Technical Data Hot Water Storage Tank unit GAU‐315EQTA Storage Capacity 315 litres Product Weight 89.4 kg Design Pressure 700 kPa Storage Tank Material Stainless Steel Outside Casing Colour Coated Zinc Steel Sanden Heat Pump – Owner’s Manual Page 12 of 16 ...
Page 13
Heat Pump Unit GAU‐A45HPA Refrigerant Type R744(CO ) Product Weight 56 kg Thermal Capacity 4.5 kw * Power Consumption 1.0 kw * COP 4.5 * Heated Water Temp. 65 C *1 Ambient Temp. (Dry / Wet) 16 C / 17 C, Inlet Water Temp. 17 C, Outlet Water Temp. 65 Sanden Heat Pump – Owner’s Manual Page 13 of 16 ...
System literature. Warranty Exclusions 1. Repair and replacement work will be carried out as set out in the Sanden Heat Pump Water Heater System warranty. However the following exclusions may void the warranty and may incur a service charge and/or cost of parts: 2.
Warranty Period Subject to the Warranty Conditions and Exclusions stated above, your Sanden Heat Pump Water Heater System is warranted as follows: Heat pump unit – Three years from date of installation Tank unit –...
You may register your product via email, to ‘registration@sanden.com.au. Simply send an email containing the same details as shown above Please Note: Similar registration details will be provided to Sanden by your supplier/installer to validate their claim for warranty support; it is essential that the dates of supply/installation correspond to within one month.