Mains Power/Electrical Installation
All Electrical Wiring should be done in accordance with the latest edition of the National
Electrical Code (NEC) and all local State/Province and Municipality codes.
The power requirement for the system is a dedicated 15 amp circuit fitted with a circuit
breaker. This circuit may be connected to constant power or off-peak power.
A local disconnect should be installed adjacent to the Heat Pump unit in accordance to
NEC and local codes.
Installation of this system must be carried out only by a qualified installation technician
(electrical or plumbing).

Electrical connections

 Breaker size and wiring must be sized per NEC rules for the rating plate amperage,
MCA and MOP.
 Power Supply is 208/230V-1Ph-60Hz
 Verify that the tank unit is full of water and the water shut off valves are open before
turning on the power.
How to connect Main Power
Remove the piping cover, terminal block cover and screw clamp fitting. (Philips head
screwdriver required)
Connect the power wiring to the terminal block per the wiring diagram/manual
Ensure ground wire is connected
Secure the power supply wiring below the terminal block with the screw clamp fitting.
Attach the terminal block cover and piping cover back on the heat pump unit.
Sanden Heat Pump – Installation Manual