INSTALLATION INSTRUCTIONS

CHECK MICROWAVE ASSEMBLY

Exhaust Adaptor (absent
C3
on models shipped for
recirculation exhaust)
• Place the microwave in its upright position, with the top
of the unit facing up.
• The microwave oven may be shipped assembled for
top exhaust (adaptor installed) or for recirculation
exhaust (adaptor absent).
• If the microwave was shipped for recirculation exhaust,
skip to C5. If shipped for top exhaust, proceed with C4.
ADAPTING MICROWAVE
BLOWER FOR RECIRCULATION
C4
1
Remove tape securing damper.
2
Raise damper flap
Remove the screw that holds the blower plate
4
to the microwave. Remove and save the screw
holding the blower motor to the microwave.
NOTE: The blower plate will be reinstalled in a
later step. The damper is not needed for recirculating
models. Save any unused parts for possible future use.
Back of
Microwave
Slip the damper
3
out of the track
on the blower
frame by pressing
and twisting
both ends.
Back of Microwave
Blower Plate
Back of
Microwave
Blower Motor
Screw
Carefully pull out the blower unit. The wires
5
will extend far enough to allow you to adjust the
blower unit.
Roll the blower unit 90° so that fan blade openings
6
are facing toward the front of the microwave.
BEFORE: Fan Blade
Openings Facing Up
AFTER: Fan Blade
Openings Facing
Forward
NOTE: Make sure wires remain routed in the grooves of
the motor frame.