(d) Range:
Ln 0 ~ 255 (FFH)
Hn 0 -255 (FFH)
Lp 0 ~ 255 (FFH)
Hp 0 ~ 255 (FFH)
Absolute position = ( Lp + Hp × 256 ) × basic unit
(e) Additional details
Depending on the value of the remainder when the current position value is
subtracted from the absolute position value set as the TOF position, the printer
executes forward or backward line feed.
When value larger than approx. 46.2 inch is selected, the setting by this command
becomes invalid.
40959201TX Rev.1
Makes MSB invalid.
Makes MSB invalid.
71 /