Mechanical Dimensions (Mm); Information Menu - Fema S40-T User Manual

Series s40 panel meter 72x36mm size for pt100 / rtd for thermocouples
Hide thumbs Also See for S40-T:
Table of Contents

Advertisement

Mechanical Dimensions (mm)

36
72
Panel
32,5
cut-out
69
Operating the Information Menu
To enter the "Information Menu" press the SQ button. The
"Information Menu" allows to visualize information and does
not allow to modify the configuration of the instrument. It is
not affected by the "PASSWord" function. During operation
with the "Information Menu", alarms remain "frozen" and are
kept on-hold. Leaving the "Information Menu" returns to the
measuring state of the instrument, without restart.
Information Menu Tree - See page 5.
Rollback - After 30 seconds without interaction from the
operator, the instrument leaves the "Information Menu".
Button SQ - Selects the visible option.
Button UP - Moves vertically along the available menu op-
tions.
Button LE - Leaves selected menu or leaves the "Informa-
tion Menu".
Information Menu Description
Configuration (Conf) - Information on the configured input
sensor and the degrees selected.
Maximum (MAX) - Value of the maximum display.
Minimum (MIn) - Value of the minimum display.
AlarmX (ALX) - Configuration of alarm X. The sequence of
information shows if the alarm is being managed ("On/Off"),
the alarm type ("Max/Min"), the setpoint, the hysteresis value,
the activation delay and the value of setpoint2 ("Off" or the
setpoint2 value).
OptionX (OptX) - Type of module installed. If there is no
module shows "nonE".
User's Manual S40-T
18
80
FEMA ELECTRÓNICA - Page 5

Information Menu

Configuration
Sensor type
8
Maximum
Minimum
Alarm1
See menu for Alarm1
See menu for Alarm1
See menu for Alarm1
Option1
Option2
ºC or ºF
Memory of maximum
Memory of minimum
"On / Off"
"Max" / "Min"
Setpoint
Hysteresis
Delay
Setpoint2
Option installed
Option installed
Counts
Seconds
Second
setpoint

Advertisement