Choke Rod

The choke is used to provide an enriched fuel mixture when starting a cold engine. It can be
opened and closed by operating the choke rod manually. Pull the rod out toward CLOSED to
enrich the mixture for cold starting.
Voltage Selector Switch
The voltage selector switches the main power carrying windings of the generator to produce
"120V ONLY" or "120/240V". If a 240V appliance is connected to the 4-prong receptacle, the
switch must be in the "120/240V" position. If only a 120V appliance is being connected to any
of the 120V 3-prong receptacles, select the "120V ONLY" position.
120/240V:
The 120V and 120/240V receptacles can be used simultaneously. 120V
Receptacles only can output half of the rated power.
120V ONLY:
ONLY the 120V receptacles can be used. Do not use the 120/240V receptacle
in this position. Rated power will be available at the 120V twist lock receptacle.
The most power will be available at the 30A 120V locking plug receptacle.
120/240V
120V ONLY
VOLTAGE SELECTOR SWITCH
WARNING:Change the Voltage Selector Switch after turning the AC circuit breaker to OFF.