data
height
Depth
Depth with hoses
RO400cV/RO400BcV/RO600cV
Width
Weight (on delivery)
Weight (filled with water)
mOdel
data
capacity *
(at water temperature 15 °c, 750
ppm), litres/minute (± 0,5)
Recommended max. usage,
litres/minute
Total power consumption (W)
Starting pressure level (bar)
Stopping pressure level (bar)
Water efficiency during operation
RequiRemenTs of inleT waTeR To The puRifieR
Inlet water flow, litres/minute
Inlet (dynamic/flowing) water
pressure, MPa (bar)
Water temperature, °c
Chemical **
conductivity, mS/m
Salt (TDS), mg/l (=ppm)
chloride (cl
), mg/l
-
cloudiness
Turbidity, fNU
ph
calcium (ca
) and
2+
Magnesium (Mg
), mg/l
2+
hardness (°d)
Iron (fe
), mgl/l
2+
Iron (fe
), mgl/l
3+
Manganese (Mn
), mg/l
2+
cOD-Mn: O
, mg/l
2
Microbiological
heterotrophic bacteria, 48 h
coliform bacteria
E. coli
* Capacity is a function of temperature; higher temp - higher flow.
** Higher values require an additional pre-treatment

teCHniCal faCts

466 mm
395 mm
460 mm
470 mm
225 mm
29 kg
33 kg
a
B
3.1
3.1
100
100
530
530
0.5
0.5
4.5
2
50-60%
50-60%
60-70%
>8
>8
0.15-1.0
0.15-1.0
0.15-1.0
(1.5-10)
(1.5-10)
(1.5-10)
2-35
2-30
<200
<1300
<1500
<7500
<900
<4500
Slight/
Slight/
distinct
distinct
<1.0
<1.0
4-10
4-10
<140.0
<140.0
<20.0
<20.0
<5.0
<5.0
<0.3
<0.3
<0.8
<0.8
<10.0
<10.0
<1000/ml
<1000/ml
<1000/ml
<10/ml
<10/ml
<1/ml
<1/ml
Electrical connection
earthed supply
Working range
Ambiente temperature
Relative humidity (Rh)
Sound level when installed
undersink cupboard
RO400
C
CV
BC
3.5
3.0
3.1
1800
1500
1500
530
530
530
3
3
0.5
4.5
4.5
50-60%
50-60%
>8
>8
>8
0.15-1.0
0.15-1.0
(1.5-10)
(1.5-10)
2-35
2-35
2-30
<200
<200
<1300
<1500
<1500
<7500
<900
<900
<4500
-
-
<0.5
<0.5
4-10
4-10
4-10
<140.0
<140.0
<140.0
<20.0
<20.0
<20.0
<1.5
<1.5
<0.3
<0.3
<0.3
<0.3
<5.0
<5.0
<1000/ml
<1000/ml
<10/ml
<10/ml
<10/ml
<1/ml
<1/ml
<1/ml
- 6 -
230 V, 50-60 hz, 10 A
2 - 35°c
25 – 95 %
<60dB(A)
BCV
C
3.0
5.2
1500
2800
530
720
0.5
3
2
2
4.5
50-60%
60-70%
>8
>10
0.15-1.0
0.20-1.0
(1.5-10)
(2-10)
2-30
2-35
<1300
<200
<7500
<1500
<4500
<900
-
-
-
<0.5
<0.5
<0.5
4-10
4-10
<140.0
<140.0
<20.0
<20.0
<1.5
<1.5
<1.0
<0.3
<0.3
<0.3
<0.3
<0.3
<0.3
<5.0
<5.0
<5.0
<1000/ml
<1000/ml
<10/ml
<10/ml
<1/ml
<1/ml
RO600
CV
4.5
2400
720
3
4.5
60-70%
>10
0.20-1.0
(2-10)
2-35
<200
<1500
<900
-
<0.5
4-10
<140.0
<20.0
<1.0
<0.3
<0.3
<5.0
<1000/ml
<10/ml
<1/ml

Hide quick links: