Fault Identification Guide - Dometic RO400 Service Manual

Reverse osmosis water purifier
Hide thumbs Also See for RO400:
Table of Contents

Advertisement

fault identifiCatiOn guide

This guide describes:
A number of symptoms as well as feasible solutions to these.
Special features regarding some of the symptoms. These notes, e.g. low inlet water temperature
are listed in the "Comments" section following the "Fault identification table".
Possible error codes on the product's display. However, depending on what is causing the problem, symptoms can appear
without error codes.
The following subjects are addressed in the following "Fault identification table":
1.
Broken diods on the printed circuit board
2.
Low water flow
3.
The water purifier does not stop even if the valve/faucet is closed
4.
The water purifier does not start/does not start to produce water.
5.
filter I, stop or warning. low pressure warning. (Possible internal leakage.)
6.
low water quality, warning/stop.
7.
Intermittent start and stop.
8.
Broken PcB.
9.
Delayed start of motor.
10.
Non normal sound
fault identifiCatiOn taBle
symptom
1.
Broken diods
2.
low water flow
a)
low inlet water
temperature
1
b)
Membrane may be
clogged
2
tROuBlesHOOting
possible error
Check/action
codes
When suspecting an error
code, perform a diode test
to verify that the code is
correct.
<Not displayed>
Measure the inlet water tem-
perature and then, compare
it with the specification at
15° c.
has the product been des-
caled recently or is the inlet
water soft?
has the product been off-
line without preservation for
an extended period of time?
Remedy
A broken diod can result in an erroneous in-
terpretation of error codes. Replace the printed
circuit board (PcB).
Estimate the flow variation due to temperature
variation. If this can explain the low flow,
a descaling may increase the flow rate. If a
service technician is present, proceed with the
system pressure measurement.
If there is reason to believe that the product
has not been descaled - descaling is recom-
mended.
If the product has been off-line without pres-
ervation - proceed with a disinfection. Then,
if a service technician is present, proceed with
system pressure measurements.