Dometic RO400 Service Manual page 27

Reverse osmosis water purifier
Hide thumbs Also See for RO400:
Table of Contents

Advertisement

symptom
g)
Alarm, too low pres-
sure due to a broken
inlet pressure sensor.
Alarm, too low pres-
h)
sure due to errone-
ously calibrated inlet
pressure sensor.
15
6.
low water quality
warning/stop.
The measured
conductivity shows that
the reduction is OK.
a)
A change in feed
water temperature or
water quality.
16
Broken TDS-sensor.
b)
tROuBlesHOOting
possible error
Check/action
codes
Verify that the connection of
the inlet pressure sensor to
the PcB is sound.
check the soldering of con-
tacts on the rear of the PcB.
furthermore, check for
oxidation on the contacts by
removing the connector and
plugging it back again.
Did the problem appear
after a power failure
- or - has the product been
disconnected and then
reconnected?
Does not reach
purification level
2-3.
Low purification
Disconnect and connect
the water purifier. Flushing
level stop.
starts and allows cold water
to enter the product.
check the TDS-sensor.
Remedy
carefully, short circuit pin 1 and 4 at the con-
nection of the pressure sensor on the PcB.
This will indicate full feed pressure and the
alarm should be turned off.
Shift the high pressure and the inlet pressure
sensor. Do not connect the "new" high pres-
sure contact. Make sure that the faucet/valve
on the pure water line is open. If this solves
the problem, reinstall the outlet pressure sen-
sor and then, replace the faulty sensor. On the
PcB, check the soldering where the pressure
sensors are connected.
Recalibrate the inlet pressure sensor, see
"
SERVIcE
If the purification is sufficient, recalibrate the
product.
check that the pins of the sensor are not bro-
ken or that the soldering at the connection to
the PcB is bad.
- 27 -
".
The product should never be
recalibrated unless water conduc-
tivity is measured and the purifi-
cation is found to be oK!

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ro400bRo400cvRo400bcRo400cRo400bcvRo600c ... Show all