Mitsubishi Electric PL18FK2 Service And Parts Manual page 89

Ductless split type air conditioners series pl ceiling cassettes series pll ceiling cassettes series pc ceiling suspended series pcl ceiling suspended series pk wall mounted series pkl wall mounted
Table of Contents

Advertisement

(1) Daily timer setting procedure
i
)Daily timer display
Each block shows timer setting of the time-period by three patterns of LED.
Lighting
......
Normal operation
Blinking
......
Setback operation
OFF
............
No operation
As an example, the left figure shows:
7.00 to 12:00, 13:30 to 2 1 :00 lighting
-
Normal operation
ii
)DAILY TIMER setting procedure
(1 ) Press
I
SET/MONITOR
I
and switchover to "set" mode.
(2) One block blinks to show the current tmie. Move the blinking block by
- 1
or
switch to the time to set.
(If there are blocks already set for "set back operation", the blocks are blinking more slowly than the current time block.)
(3) Set the timer for each block as follows :
[For operation ON
1 - p r e s m + t h e
block lights-the next block blinks.
[For SET BACK operation]-press
/
SET
BACK
1-the block blinks-the next .block blinks.
[For operation OFF
]-.press /-the
block turns OFF-the next block blinks.
Continuous pattern setting can be done by pressing the switch continuously.
(2) WEEKLY TIMER setting procedure
i
)Weekly timer display
Upper row
...
A lighting LED shows "today".
Lower row
...
Each LED displays if the daily timer is ON or OFF.
ii
)Weekly timer setting procedure
(1
)
Press
1
SET/MONITOR
I
and switch over to "SET mode.
(2) Today's LED blinks in the lower row. To apply the daily timer, press the WEEKLY TIMER
/ONI
switch. Not to apply the daily timer, press the WEEKLY TIMER
switch.
(3) Then the next LED blinks. Set in the same way as (2).
(4) Repeat procedure as described in (2) and (3) until all of 7 days are set.
(5)
When setting is completed, press
I
SET/MONITOR
I
switch to return to "MONITOR"
mode.
2 . T I M E R ADAPTER
With the optional timer adapter (PAC-71 5AD), a timer on the market can be connected. Connect the timer adapter to the
remote controller and wire as shown in the below figure. If more than 33 feet of wiring is needed to connect the remote
controller and the timer, use a relay.
NOTE: Be sure to use a non-voltage contact output timer with load and timer power supply having different circuits.
&/Timer
Adapter
(Wiring)
T...Timer Contact
ORANGE
. - - - - -
- -
SW...Swit~h
remote
From
l - q
.
--&j
1 Independent Timer Operation
controller
I
.
------
Remote controller operation switch becomes idle.
BROWN
2.Combined Use of Timer and Remote Controls
From
ORANGE
.
-------
SW ON Timer control
controller
remote
RED+
- - - I c + !
SW OFF Remote Control Operation
- E
BROWN
s w
*
--e\J