MODEL FTGF1P (120 VAC)
SUMMARY
u

OPTIONS SELECTION

At the back of the thermostat, there are two selection switches to set
your preference.
1
Temperature in °C or °F.
2
Time in 12 or 24 hours.
u

TO SET TIME AND DAY

Press on DAY, HOUR and MIN buttons to adjust time and day.
u
TO RECORD THE
Select chosen setpoint temperature by using
button (2 to 3 seconds) until icon appears on display.
u
TO RECORD THE
Select chosen setpoint temperature by using
Press on
button (2 to 3 seconds) until icon appears on display .
u
Adjust the setpoint temperature until heating indicator (
display. Press on TEST button. The test is conclusive if the warning light
(GFI) on thermostat is ON and power to the load is cut-off (
on display though). If these events do not occur, check the installation.
Press on RESET button to reset the GFCI.
u
To select an operating mode, use MODE button.
AUTO:
Runs the program.
and can temporarily override your programming up to the
next program.
MAN:
Maintains the selected temperature.
the temperature setting.
(COMFORT) SETPOINT TEMPERATURE
(ECONOMIC) SETPOINT TEMPERATURE
or
shows temperature setting
or
button. Press on
or
button.
) appears on
remain
or
changes

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FTGF1P and is the answer not in the manual?

Questions and answers

Summary of Contents for Nuheat FTGF1P

  • Page 1 MODEL FTGF1P (120 VAC) SUMMARY OPTIONS SELECTION At the back of the thermostat, there are two selection switches to set your preference. Temperature in °C or °F. Time in 12 or 24 hours. TO SET TIME AND DAY Press on DAY, HOUR and MIN buttons to adjust time and day.
  • Page 2 (line) of the load will be cut-off. Connect thermostat as shown on diagram. A certified electrician must install the thermostat. PARTS INCLUDED - One (1) FTGF1P (120 VAC) thermostat - Two (2) 6-32 screws - Four (4) solderless connectors (for copper wire)
  • Page 3 1) Connecting wires and mounting thermostat Connect the rear thermostat wires to the power supply and to the load using solderless connectors for copper wires. See schematic diagram. Push the excess wire back into the electrical box to prevent inter- ference with thermostat.
  • Page 4: Operating Modes

    OPERATING MODES The FTGF1P has two (2) operating modes. ANUAL This mode allows you to maintain a constant temperature on the floor. 1- To activate this mode, press on Mode button to display the icon.
  • Page 5 Schedule programming The FTGF1P allows 4 setting changes for each day of the week. There are no presset programs.The programs are tailored to perfectly adapt to your life style. The principle is very simple. For each day, enter the time at which you wake up (P1), the time you leave for work (P2), the time you arrive back home (P3) and the time you go to bed (P4).
  • Page 6 Mode Program Time Wake-up time Leaving time Return time Bed time NOTE : For temperature increases (Prog. 1 and 3), allow at least 1 hour. If you have lowered the temperature during the night and you wake up at 7:00 AM, change the setting to 6:00 AM. a) To Program your Schedule 1- Press on PGM button to access the programming mode.
  • Page 7 Mode button. If you wish to immediately return to the programmed settings, press on Mode button twice. CHARACTERISTICS • Model: FTGF1P (120 VAC) • Supply: 120 VAC, 50/60 Hz • Load: 16.7 A maximum (Resistive only) • Power: 2000 watts (NI) @ 120 VAC •...
  • Page 8 During this period, NUHEAT will repair or replace the product with a new or of equivalent quality at NUHEAT’S option, without charge, any product proven defective in normal use.

Table of Contents