MT VERNON-AE TROUBLE SHOOTING MANUAL
CONTROL BOARD SPECS 7.5 CODE: (Rev 2 fuel tables)
FUEL
CORN:
UTILITY PELLET:
SOFTWOOD:
SUNFLOWER SEEDS: 3
WHEAT:
HARDWOOD PELLET: 5
*NOTE: AUTOCLEAN CYCLES TIMES ARE ESTIMATED WHEN THE UNIT IS RUN AT THE "HIGH" OUTPUT SETTING.
UPDATES:
SRV7000-323
ECO 56401 --- CHANGED FROM 6.9 TO 6.10A CODE. INSTALLED POWER STROKE CODE FOR AUTOCLEAN AND
CHANGED TO THE "QUIET" CONVECTION BLOWER CURVE. REV 2 FUEL TABLES ALSO INSTALLED. (1-11-07)
SRV7000-330
ECO 56476 -- RELEASED WITH THE 7.2 CODE. HIGH ELEVATION FUEL TABLES INSTALLED. 2 CONVECTION
BLOWER SPEED OPTIONS INSTALLED, 135 & 165 DEGREES TO GET TO THE HIGH BLOWER SPEED & EXHAUST
BLOWER STAYS ON DURING THE AUTO-CLEAN CYCLE AND 20 MINUTES AFTER AUTO-CLEAN IS COMPLETED.
(8-2-07 // SN 0072232364 INSERT /// SN 0072279399 FS)
SRV7000-456
ECO 58315 -- RELEASED WITH THE 7.3 CODE
REV B --- RELEASED WITH THE 7.4 CODE. ADDRESSED PREVIOUS AUTO-CLEAN PROBLEMS. SN 00700200343
REV C --- RELEASED WITH THE 7.5 CODE. ADDRESSED LOGIC PROBLEM WITH VAC SWITCH & AUGER JAM.
4-24-08
CONTROL BOARD
SRV7000-456 Rev C
UFTI
SS LOW SS MED MAX IGNITER TIME
0
14 MIN
12 MIN
1
4 MIN
5 MIN
2
4 MIN
5 MIN
4 MIN
5 MIN
4
10 MIN
10 MIN
4 MIN
5 MIN
14 MIN
4 MIN
4 MIN
4 MIN
10 MIN
4 MIN
PAGE 7
A/C CYCLE TIME
SHUTDOWN TIME
2.4 HRS*
1.2 HRS*
3.2 HRS*
2.4 HRS*
1.8 HRS*
2.1 HRS*
10 MIN
10 MIN
10 MIN
10 MIN
10 MIN
10 MIN
7020-057C