Office/Conference Room With Carpet On The Floor - McQuay MFU-C Product Manual

Chilled water fan coils
Hide thumbs Also See for MFU-C:
Table of Contents

Advertisement

4 PIPES
MODELLI
Nominal Air Flow
(High/Medium/Low)
Available Static Pressure
5
Total Cooling Capacity
5
Total Sensible Capacity
Water Flow Rate
Water Pressure Drop - Cooling
6
Heating Capacity
Water Flow Rate
Water Pressure Drop - Heating
7
Lp (Sound Pressure Level)
Power Supply
Fan N° .
4
Max Power Supply
Cond. Drain Connections
Water Connections
Total volume
Weight [with package]
Weight with cabinet [with
package]
Dimens. unit (WxHxD)
Dimens. with cabinet (WxHxD)
NOTES
4 Nominal Air Flow; High Fan Speed
5 At the following nominal conditions: nominal air flow; 7/12° C inlet/outlet water temperature; 27° C db / 19° C wb inlet air temperature; High speed
6 At the following nominal conditions: nominal air flow; 70/60 ° C inlet/outlet water temperature; 20° C inlet air temperature; High speed
7 At High/Medium/Low speed; nominal air flow; measured in a room of 100 m volume and 0.5 sec. reverberation time ( e.g. office/conference room with carpet on the floor)
CHILLED WATER FAN COILS MF – McQuay FCF PM05D_ENG
012H
020H
254/215/
369/321/
3
m
/h
176
240
Pa
--
--
1.2
1.8
kW
0.9
1.4
kW
0.057
0.084
l/s
kPa
4
5
2.3
2.9
kW
0.057
0.071
l/s
kPa
11
18
dB(A)
38/35/32
42/37/32
V/ph/Hz
1
1
kW
0.021
0.050
mm
20
20
inches
3/4"
3/4"
litres
[0.792 + 0.264]
kg
24 [26]
kg
26 [27]
704x540x224
mm
910x539x230
mm
TECHNICAL DATA
025H
035H
050H
445/330/
677/545/
811/663/
250
380
456
--
--
--
2.5
3.5
4.6
1.7
2.5
3.4
0.118
0.165
0.219
8
15
26
4.3
5.6
7.0
0.104
0.137
0.172
30
18
35
41/34/31 47/43/38
47/39/31
220~240/1/50
2
2
2
0.051
0.056
0.077
20
20
20
3/4"
3/4"
3/4"
[1.158 + 0.386]
[1.525 + 0.508]
28 [30]
30 [33]
31 [35]
35 [40]
904x540x224
1104x540x224
1110x539x230
1310x539x230
3+1 ROWS
060H
080H
090H
1300/
1450/
1068/915/
1063/
1248/
672
824
1078
--
--
--
5.7
6.9
8.0
4.4
4.9
5.2
0.271
0.32
0.345
16
15
17
8.6
12.0
13.0
0.209
0.216
0.339
40
24
14
53/48/41
51/47/41
53/50/47
2
3
3
0.107
0.140
0.161
20
20
20
3/4"
3/4"
3/4"
[1.89 + 0.63]
35 [39]
45 [50]
1304x540x224
1510x539x230
page 8/36

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mfu-hMfc-cMfc-h

Table of Contents