Technical specifications

Output power: typical: 700mW, guaranteed: 470mW, 100mW 632nm green,
70mW 473nm blue, 300mW 650nm red
Lasersources: aircooled DPSS laser
Laser class: 4
Modes: ILDA, DMX 512
ILDA: 25pin ILDA standard Sub-D shaped 25pin connector
Galvos: 50k scanspeed
DMX 512: 16 channels
Patterns: 160
Scanangle: set to ca. 40° optical (60° max)
Beam: ca. 3mm/1mrad
Accessories: power cable, key switch, interlock plug, manual, safety cord
The laser comes in a flightcase.
Input voltage: AC 100~240V 50/60Hz
Power consumption: 145W
Size: 670 x 380 x 270 mm (W x D x H)
Weight: 20kg Laser, total: 35kg (with flightcase)
Operating temperature: 10°-35°C
Temperatur: 10°-35°C

Change scanner

1. Unscrew UK M6 screws and
disconnect signal cable.
2. Loosen M4 x 10 screw and remove
galvo.
3. Insert galvo, reconnect and fix
signal cable.
4. Rotate galvo to center projection.
Fix galvo.

Adjustable mirror mounts

1. Loosen setscrews, then adjust with X/Y
adjustable screws. Make sure beam is
centered on scanner mirrors.
2. Adjust Z-screw simultaneously.
3. Tighten setscrews.
4. When combining beams (RGY/RGB
laser), first make sure the beams are
(roughly) on the same spot on the
mirrors/dichros. Then use a test pattern
(e.g. rectangle) to do fine adjustment.
For adjustments, always turn output
power down (if possible).