Wolf ICBDF304 series Installation Instructions Manual page 7

Dual fuel ranges
Hide thumbs Also See for ICBDF304 series:

Advertisement

I N S TA L L AT I O N
I N S T R U C T I O N S
1 5 2 4 m m
D U A L F U E
L R A N G E S
I C B D F 6 0 6 C F
I
C
B
D
F
6
0
4
C
F
I N S T A L L A T I O N S P E C I F I C A T I O N S
NOTE
A
937 mm
OVERALL
HEIGHT TO
COOKING
SURFACE
1527 mm
OVERALL WIDTH
VENTILATION HOOD
600 mm
min
COUNTERTOP
TO COMBUSTIBLE
MATERIALS
600
mm
min TO
762 mm
914 mm
min
max
FOR CHARBROILER
TO BOTTOM OF
VENTILATION HOOD
1530 mm
FINISHED ROUGH OPENING WIDTH
254 mm
LOCATION
83 mm
OF GAS
787 mm
SUPPLY
LOCATION OF GAS AND
330 mm
ELECTRICAL EXTENDS 76 mm
LOCATION OF
ON FLOOR FROM BACK WALL
ELECTRICAL
749 mm
OVERALL DEPTH
699 mm
235
mm
1445
mm
WITH
254 mm
RISER
616 mm
1191
mm
911
WITH
mm
641 mm
254 mm
RISER
1064
mm
WITH
127 mm
RISER
1194 mm
LEGS AND CASTERS ALLOW
54 mm HEIGHT ADJUSTMENT
330 mm
max
457 mm
min
TO COUNTERTOP
NOTE
B
914
mm
937 mm
TO
COOKING
SURFACE
ISLAND INSTALLATIONS: 305 mm MINIMUM
CLEARANCE FROM BACK OF RANGE TO
COMBUSTIBLE REAR WALL ABOVE COUNTERTOP–
50 mm TO NON-COMBUSTIBLE MATERIALS
O V E R A L L D I M E N S I O N S
Overall Width
1527 mm
Overall Height
(to cooking surface)
937 mm
Overall Depth
749 mm
Opening Width
1530 mm
Dimensions may vary to ± 3 mm.
IMPORTANT NOTE: In non-island applications, a
minimum 254 mm riser is required for all 1524 mm
models installed against a combustible surface.
The island trim and 127 mm riser may only be used
against a non-combustible surface.
Note A:
Side clearances. If the distance
measured from the periphery of the
nearest burner to any vertical surface
is less than 200 mm, the surface shall
be protected in accordance with
AS/NZ5601.
Note B:
The rangehood fitted above the
cooktop must be installed according
to the installation instructions for
the rangehood. A minimum
distance of 750 mm is required for a
range hood and 750 mm for an
exhaust fan
.
7