Download Print this page

Wolf ICBDF304 series Installation Instructions Manual page 13

Dual fuel ranges
Hide thumbs Also See for ICBDF304 series:

Advertisement

I N S TA L L AT I O N
I N S T R U C T I O N S
S E R V I C E
I N F O R M A T I O N
When requesting information, literature,
replacement parts or service, always refer to
the model and serial number of your dual fuel
range. This information is found on the
product rating plate located rear of the remov-
able lower panel. Refer to the illustration below.
Record the rating plate information
below for future reference.
GSCS20230
GSCS20230
SAI GLOBAL
Made in USA
SAI GLOBAL
AS4551
AS4551
Model No: ICBDF304
Model No: ICBDF366
Serial No:
Serial No:
Gas type
NG
LPG
Gas type
Test point press. (kPa)
1.0
2.75
Test point press. (kPa)
Injector sizes (mm)
Injector sizes (mm)
RHF
1.80
1.09
RHF/CF
RHR
1.80
1.09
RHR/CR
LHF
1.80
1.09
LHR
1.35
0.89
LHF
LHR
Total Consumption (MJ/h)
Total Consumption (MJ/h)
51.0
51.1
Electrical compliance: in accordance with
Electrical compliance: in accordance with
AS/NZS3100 240 V AC, 4.5 kW/19 Amps, 50 Hz
AS/NZS3100 240 V AC, 4.5 kW/19 Amps, 50 Hz
Imported & distributed by
Imported & distributed by
Suite 1, 151 Barkley Avenue. Burnley VIC 3121
Suite 1, 151 Barkley Avenue. Burnley VIC 3121
t: +61 3 9421 0232
t: +61 3 9421 0232
GSCS20230
GSCS20230
SAI GLOBAL
SAI GLOBAL
Made in USA
AS4551
AS4551
Model No: ICBDF486C
Model No: ICBDF484F
Serial No:
Serial No:
Gas type
Gas type
NG
LPG
Test point press. (kPa)
Test point press. (kPa)
1.0
2.75
Injector sizes (mm)
Injector sizes (mm)
RHF
RHF
1.80
1.09
RHR
1.80
1.09
RHR
French top
1.80
1.09
Grill
LHF/CF/CR
LHF
1.80
1.09
LHR
1.35
0.89
LHR
Total Consumption (MJ/h)
65.0
65.1
Total Consumption (MJ/h)
Electrical compliance: in accordance with
Electrical compliance: in accordance with
AS/NZS3100 240 V AC, 8.4 kW/35 Amps, 50 Hz
AS/NZS3100 240 V AC, 8.4 kW/35 Amps, 50 Hz
Imported & distributed by
Imported & distributed by
Suite 1, 151 Barkley Avenue. Burnley VIC 3121
Suite 1, 151 Barkley Avenue. Burnley VIC 3121
t: +61 3 9421 0232
t: +61 3 9421 0232
I M P O R T E D &
D I ST R I B U T E D B Y :
MultyFlex
C O N T A C T
I N F O R M A T I O N
Website:
www.multyflex.com. au
Model Number
Serial Number
Installation Date
Wolf Dealer and Phone
GSCS20230
SAI GLOBAL
Made in USA
Made in USA
AS4551
Model No: ICBDF364C
Serial No:
NG
LPG
Gas type
NG
LPG
1.0
2.75
Test point press. (kPa)
1.0
2.75
Injector sizes (mm)
1.80
1.09
RHF
1.80
1.09
1.80
1.09
RHR
1.80
1.09
Grill
1.78
1.09
1.80
1.09
LHF
1.80
1.09
1.35
0.89
LHR
1.35
0.89
79.0
79.1
Total Consumption (MJ/h)
66.0
66.1
Electrical compliance: in accordance with
AS/NZS3100 240 V AC, 4.5 kW/19 Amps, 50 Hz
Imported & distributed by
Suite 1, 151 Barkley Avenue. Burnley VIC 3121
t: +61 3 9421 0232
GSCS20230
SAI GLOBAL
Made in USA
Made in USA
AS4551
Model No: ICBDF486G
Serial No:
NG
LPG
Gas type
NG
LPG
Test point press. (kPa)
1.0
2.75
1.0
2.75
Injector sizes (mm)
RHF/CF
1.80
1.09
1.80
1.09
RHR/CR
1.80
1.09
1.80
1.09
Griddle
1.70
1.09
1.78
1.09
LHF
1.80
1.09
1.80
1.09
LHR
1.35
0.89
1.35
0.89
Total Consumption (MJ/h)
94.0
94.1
94.0
94.1
Electrical compliance: in accordance with
AS/NZS3100 240 V AC, 8.4 kW/35 Amps, 50 Hz
Imported & distributed by
Suite 1, 151 Barkley Avenue. Burnley VIC 3121
t: +61 3 9421 0232
The information and images in this book are the
copyright property of Wolf Appliance, Inc., an
affiliate of Sub-Zero, Inc. Neither this book nor any
information or images contained herein may be
copied or used in whole or in part without the
express wr i tten permission of Wolf Appliance, Inc.,
an affiliate of Sub-Zero, Inc.
©Wolf Appliance, Inc. all rights reserved.
B E F O R E C A L L I N G F O R S E R V I C E
Before calling your Wolf dealer, refer to the
troubleshooting guide on page 12. Check
the household fuse or circuit breaker to see if it
has been blown or tripped and that the electri-
cal connection to the appliance has not been
disconnected. A power outage may also have
caused a disruption in service.
1300 808 859
For service call:
GSCS20230
GSCS20230
SAI GLOBAL
SAI GLOBAL
Made in USA
AS4551
AS4551
Model No: ICBDF484CG
Model No: ICBDF364G
Serial No:
Serial No:
Gas type
Gas type
NG
LPG
Test point press. (kPa)
Test point press. (kPa)
1.0
2.75
Injector sizes (mm)
Injector sizes (mm)
RHF
1.80
1.09
RHR
1.80
1.09
Griddle
1.70
1.09
Griddle
LHF
1.80
1.09
LHR
1.35
0.89
Total Consumption (MJ/h)
66.0
66.1
Total Consumption (MJ/h)
Electrical compliance: in accordance with
Electrical compliance: in accordance with
AS/NZS3100 240 V AC, 4.5 kW/19 amps, 50 Hz
AS/NZS3100 240 V AC, 8.4 kW/35 Amps, 50 Hz
Imported & distributed by
Imported & distributed by
Suite 1, 151 Barkley Avenue. Burnley VIC 3121
Suite 1, 151 Barkley Avenue. Burnley VIC 3121
t: +61 3 9421 0232
t: +61 3 9421 0232
GSCS20230
GSCS20230
SAI GLOBAL
SAI GLOBAL
Made in USA
AS4551
AS4551
Model No: ICBDF604CF
Model No: ICBDF606CG
Serial No:
Serial No:
Gas type
Gas type
NG
LPG
Test point press. (kPa)
1.0
2.75
Test point press. (kPa)
Injector sizes (mm)
Injector sizes (mm)
RHF/CF
RHF
1.80
1.09
RHR
1.80
1.09
RHR/CR
Grill
1.78
1.09
Grill
Griddle
French top
1.80
1.09
LHF
1.80
1.09
LHF
LHR
1.35
0.89
LHR
Total Consumption (MJ/h)
Total Consumption (MJ/h)
80.0
81.1
Electrical compliance: in accordance with
Electrical compliance: in accordance with
AS/NZS3100 240 V AC, 9.1 kW/38 Amps, 50 Hz
AS/NZS3100 240 V AC, 9.1 kW/38 amps, 50 Hz
Imported & distributed by
Imported & distributed by
Suite 1, 151 Barkley Avenue. Burnley VIC 3121
Suite 1, 151 Barkley Avenue. Burnley VIC 3121
t: +61 3 9421 0232
t: +61 3 9421 0232
W I R I N G
D I A G R A M
The wiring diagram covering the control circuit
is located rear of the removable lower panel.
Made in USA
NG
LPG
1.0
2.75
RHF
1.80
1.09
RHR
1.80
1.09
Grill
1.78
1.09
1.70
1.09
LHF
1.80
1.09
LHR
1.35
0.89
81.0
81.1
Made in USA
NG
LPG
1.0
2.75
1.80
1.09
1.80
1.09
1.78
1.09
1.70
1.09
1.80
1.09
1.35
0.89
109.0
109.1
13