Covering the following models:
Model
Matt Black
Ivory Enamel
Ivory White Enamel
Majolica Brown
Black Enamel
Model
Gas
CAT.
DV-425CFNG
I
2H
DV-425CFLPG
I
3P
Minimum Flue Specification T260 / N2 / 0 / D / 1
Maximum Flue Temperature 180°C
Packing Checklist
Qty Description
1
Stove
1
Flue Blanking plate
1
Log set (5 logs)*
2
Ash Panels* (2 sections)*
1
Fixing Kit Containing
1 Instruction Manual
*Packed in appliance
Technical Specification
Gas Type
Working
NOX
Pressure
Class
Natural
20mbar
3
(G20)
Propane
37mbar
3
(G31)
Flue Outlet Size 127mm (5") Ø
Gas Inlet Connection Size 8mm Ø
1

Installation Instructions

NATURAL GAS
DV-425CFNG
DV-425CFNGIV
DV541-076
DV-425CFNGMJ
DV-425CFNGBK
Aeration
Injector
1 x 14.5mm
2 x 11.5mm
Efficiency Class II - 78%
608
LPG
DV-425CFLPG
DV-425CFLPGIV
DV541-479
DV-425CFLPGMJB
DV-425CFLPGBK
Gas Rate
Input kW (Gross)
3
m
/h
High
375
0.623
6.6
165
0.232
6.4
32
369
Country
Low
3.6
GB, IE
3;6
GB, IE
9