Dovre 525CB Installation Instructions And Operating Manual

Dovre 525CB Installation Instructions And Operating Manual

Wood stove
Hide thumbs Also See for 525CB:

Advertisement

INSTALLATIEVOORSCHRIFTEN  EN GEBRUIKSAANWIJZING
INSTALLATION INSTRUCTIONS AND OPERATING MANUAL
INSTALLATION ET MODE D'EMPLOI
EINBAUANLEITUNG UND GEBRAUCHSANWEISUNG
INSTRUCCIONES DE INSTALACIÓN Y USO
525CB
HOUTKACHEL
WOOD STOVE
POELE A BOIS
HOLZ-FEUERSTÄTTE
ESTUFA DE LEÑA
03.27696.100 - 02-2013

Advertisement

Table of Contents
loading

Summary of Contents for Dovre 525CB

  • Page 1 INSTALLATIEVOORSCHRIFTEN  EN GEBRUIKSAANWIJZING HOUTKACHEL WOOD STOVE INSTALLATION INSTRUCTIONS AND OPERATING MANUAL INSTALLATION ET MODE D’EMPLOI POELE A BOIS HOLZ-FEUERSTÄTTE EINBAUANLEITUNG UND GEBRAUCHSANWEISUNG INSTRUCCIONES DE INSTALACIÓN Y USO ESTUFA DE LEÑA 525CB 03.27696.100 - 02-2013...
  • Page 2: Table Of Contents

    Removing ashes Fog and mist Solving problems Maintenance Chimney Cleaning and other regular maintenance activities Spare parts 525CB Appendix 1: Technical data Appendix 2: Measurements Appendix 3: Distance from combustible material Appendix 4: Diagnostic diagram Index Subject to change because of technical improvements...
  • Page 3: Introduction

    The appliance is intended for use in a living room. It should be connected hermetically to a well- functioning chimney. that the wood stove 525CB has been produced in We advise you have the appliance installed by an conformity with EN 13240.
  • Page 4: Safety

    Safety Installation Please note: All safety regulations must be complied with strictly. requirements Please read carefully the instructions supplied with the appliance for installation, use and maintenance, before using the appliance. General The appliance must be installed in accordance The appliance must be connected tightly to a well- with the laws and requirements of your functioning chimney.
  • Page 5: Ventilation Of The Area

    A draught/vacuum of 15 - 20 Pa during normal Ventilation of the area operation is ideal. For good combustion, the stove needs air (oxygen). Starting from the flue spigot, the flue must run as This air is supplied via adjustable air inlets from the vertically as possible.
  • Page 6: Product Description

    between the connecting tube and combustible 6. Leg material. 7. Primary air slide The rule of thumb for a single-walled tube is a distance of 3x the diameter. If a lining shell is Door lock fitted around the tube, a distance of 1x the diameter is permissible.
  • Page 7 Connecting to the rear 1. Apply supplied fibre glass sealing tape (2) measuring 10 x 3 mm to the contact surface of the connection collar (8). 2. Remove the protection plate from the back shield with the assistance of a screwdriver; see following figure.
  • Page 8: Preparing The Outside Air Connection

    09-20008-006 09-20008-007 Connect to top Preparing the outside air Upon provision, the connection is fitted at the back, connection therefore you need not install a cover on the back. If the appliance is installed in a room without sufficient ventilation, you can install the connecting kit on the Because of the distance to the (combustible) wall, the protection plate may not be removed in the appliance for the supply of outside air.
  • Page 9: Use

    2. Connect the appliance airtight to the flue Use seasoned wood that contains no more than (chimney). 20% moisture. The wood should have been seasoned for at least 2 years. 3. In the case of connection to outside air: connect the outside air supply to the connector fitted to the Saw the wood to size and split it while it is still appliance.
  • Page 10: Burning Wood

    4. Close the door of the appliance and open the Open stacking primary air inlet and the secondary air inlet of the appliance; see the following figure. 5. Allow the fire develop into a good blaze until there is glowing bed of charcoal. You can then add fuel and adjust the appliance, see the chapter "Stoking with wood".
  • Page 11: Controlling Combustion Air

    the stove window and door. Controlling combustion air When the outside temperature is not very low, it is better to burn wood intensely for a few The appliance has various features for air control; see hours instead of having a low intensity fire for a following figure.
  • Page 12: Fog And Mist

    Chimney In many countries, you are required by law to have your chimney checked and maintained. At the beginning of the heating season: have the chimney swept by an expert. During the heating season and after the chimney has not been used for a long time: have the chimney checked for soot deposits.
  • Page 13: Spare Parts 525Cb

    1. Remove dust and loose soot with a dry cloth. form bubbles, resulting in a new air leak. 2. Clean the glass with stove glass cleaner: Spare parts 525CB a. Apply stove glass cleaner to a kitchen sponge, rub down the entire glass surface and give the cleaning agent time to react.
  • Page 14: Appendix 1: Technical Data

    Appendix 1: Technical data Model 525CB Nominal output 8 kW Flue connection (diameter) 150 mm Weight +/- 120 kg Recommended fuel Wood Fuel property, max. length 40 cm Mass flow of flue gases 5.4 g/s Flue gas temperature measured in the measurement 297°C...
  • Page 15: Appendix 2: Measurements

    Appendix 2: Measurements 525CB 09.00267.000 Subject to change because of technical improvements...
  • Page 16: Appendix 3: Distance From Combustible Material

    Appendix 3: Distance from combustible material 525CB - Minimal distance in millimeters 09-20008-015 Protective (insulated) connection pipe Combustible material Incombustible material, thickness 100 mm Please note! To guarantee the flow of combustion air, when no outside air connection is provided, the distance from the outside air connection collar to the wall must be at least 20 mm.
  • Page 17 525CB - Dimensions of fireproof protective plate 09-20002-004 Minimal dimensions of fireproof protective plate A (mm) B (mm) Din 18891 Germany Finland Norway Subject to change because of technical improvements...
  • Page 18: Appendix 4: Diagnostic Diagram

    Appendix 4: Diagnostic diagram Problem Wood will not stay lit Gives off insufficient heat Smoke emissions into the room when adding wood Fire in stove is too intense, is hard to adjust Deposit on the glass Possible cause Possible solution A cold flue usually fails to create sufficient draught.
  • Page 19: Index

    Index Connection to chimney at top Connection to supply of outside air Adding fuel Control air supply Adding wood smoke emissions into the room Control of air Air control Cover on flue Air inlets Creosote Air leak Air supply for fire Damage Ash pan Damp wood...
  • Page 20 Flue gas Mist, do not burn wood mass flow temperature Nominal output 12, 14 Fog, do not burn wood Fuel adding Open adding wood ash pan necessary amount ash removal port suitable door unsuitable wood Outside air intake connection to Glass clean Paint finish...
  • Page 21 Temperature Unsuitable fuel Ventilation connect supply of outside air rule of thumb Ventilation louvre Vermiculite inner plates Walls fire safety Warning chimney fire 4, 9, 11 combustible materials fireproof inner plates glass broken or cracked 4, 13 hot surface regulations stove window cleaner terms and conditions for insurance ventilation...