Sharp R-22AT Service Manual page 29

Commercial
Hide thumbs Also See for R-22AT:
Table of Contents

Advertisement

PAD ORDER
DISPLAY
(Door close)
SET
SET
"NUMBER"
(within 2 sec.)
1
NUMBER 1
5
NUMBER 1
SET
"NUMBER"
SET
Enter the memory information into the memory pads 1
~10 referring to above example. The memory information
are given below.
Memory No.
Cook Time
1
2
3
4
5
6
7
8
1 min. 15 sec.
9
1 min. 30 sec.
10
11-20
3) How to enter the EEPROM pad.
Enter the EEPROM data into the memory pads, 3, 4,6, 8,
9, 11, 12, 13, 14, 15 and 20, referring to following example
and the table of EEPROM data.
Example: Suppose the EEPROM dada "2235" is entered
in to the memory pad 3.
PAD ORDER
(Door close)
CHECK
"NUMBER"
CHECK
(User"s Total Counts)
#1
VOLUME
VOLUME
DOUBLE
QUANTITY
(Total Counts of Service)
3
SET
2, 2, 3, 5
SET
CHECK
#1: Denotes the procedure for the servicer to disable clearing.
This procedure is instructed to service personnel only and
is excluded from the operation manual.
#2: If the IC-2 is exchanged, 0 should be indicated instead of
8268. But if the control unit is exchanged, 0 is not always
indicated.
#3: Total counts of Service, 6 figures will be displayed.
PHONE
• 0
• 5
Output Power
5 sec.
100%
10 sec.
100%
20 sec.
100%
30 sec.
100%
40 sec.
100%
50 sec.
100%
1 min.
100%
100%
100%
2 min.
100%
0 sec.
"
" : Flicker /
: 0.1 sec BUZZER
DISPLAY
PHONE
CHECK
#2
8268
"CHECK"
#2
8268
"CHECK"
#2
8268
"CHECK"
#3
xxxxxx "CHECK"
3030 "CHECK"
0 "CHECK"
2235 "CHECK"
x4
2235 "CHECK"
Table of EEPROM data
Memory
pad
Data
3
2 2 3 5 Hiher temperature limit setting of magn-
etron thermistor detection.
4
0 0 0 0 Constant setting of fan lock detection.
6
0 1 0 0 Time setting of fan lock detection.
8
3 2 0 0 Hiher temperature limit setting of ex-
haust air detection.
9
0 0 0 0 Constant setting of fan lock detection.
11
0 0 0 0 Constant setting of magnetron thermis-
tor detection.
12
0 0 0 0 Constant setting of magnetron thermis-
tor detection.
13
0 0 0 0 Constant setting of magnetron thermis-
tor detection.
14
0 0 0 0 Constant setting of magnetron thermis-
tor detection.
15
1 5 Interval time setting of magnetron ther-
mistor detection.
20
0 0 0 0 Switching level setting of magnetron ther-
mistor detection.
OTHER CHECKING AND CLEARING PROCE-
DURE FOR R-24AT / R-22AT
1) To check the contents of defrost.
PAD ORDER
(Door close)
CHECK
"NUMBER"
DEFROST
CHECK
#1 : No key entry signal.
2) How to clear all counter(user and service) and total
cooking time and used time of filter.
PAD ORDER
(Door close)
SET
SET
"NUMBER" •
DOUBLE
"NUMBER" • DOUBLE
CHECK
"NUMBER" • DOUBLE
VOLUME
"NUMBER" • DOUBLE
SET
27
Contents
"
" : Flicker /
: 0.1 sec BUZZER
DISPLAY
PHONE
CHECK
1
0.20 DEF
CHECK
(A)
DEF
CHECK
1
20
POWER
(+ - B)
50%
2
0.13 DEF
CHECK
(A)
DEF
CHECK
2
30
POWER
(+ - B)
30%
DEF
CHECK
3
5
POWER
20%
(Repeat)
DISPLAY
PHONE
R - 2 2 A T
R-23AM
R - 2 4 A T