AXIS 215 PTZ-E Installation Guide
Installation
Wall mounting
1. Using the drill template provided, drill four holes on the wall.
2. Place the AXIS 215 PTZ-E network camera to the wall and attach it using four screws
appropriate to the wall material.
Ceiling mount
1. Remove the wall bracket by unscrewing the four screws attached to it, using the 5-mm allen
key provided.
2. Remove the sunshield (optional) by unscrewing the three screws attached to it, using the 2-mm
allen key provided.
3. Screw the NPT adaptor onto a pole in the ceiling.
4. Attach the AXIS 215 PTZ-E network camera to the NPT adaptor using the four large screws.
Connecting the cables
1. Connect the 5m-power cable to a power connector (100-240VAC, 1.2A, 50/60Hz) using the
three wires - L, N, and GND.
2. Connect the camera to the network using the 5m CAT5E network cable.
Please refer to the Assign an IP address chapter in the AXIS 215 PTZ installation guide to assign an
IP address to the camera.
Note - Appropriate protection is required for the power and Ethernet cable in the case of out-
door installation.
INPUT
100-240VAC
L
N
GND
brown
blue
yellow-green
Page 5