Dimplex DFI400R Owner's Manual page 7

Hide thumbs Also See for DFI400R:
Table of Contents

Advertisement

Installation
Figure 2
Installation
Surface
6.7 in.
(170mm)
Air Inlet
DFI400: 100cm
DFI600: 150cm
New Construction
1. Mark the desired location on
the floor and store the fireplace
in a safe, dry and dust free
location.
2. Use studs to frame
sure with the following mini-
mum internal/opening dimen-
sions (Figure 2).
!
NOTE: An air inlet is required
for optimum mist production, see
Figure 2 for minimum dimen-
sions.
!
NOTE: For optimal perfor-
mance, 12 in. (305 mm) mini-
mum clearance between the in-
stallation surface and any surface
above should be maintained.
3. Secure unit through the two
holes in the bottom of the unit
into supports to prevent the
2
2
an enclo-
DFI400: 15.75 in. (400mm)
DFI600: 22.05 in. (560mm)
Supports: 0.75 in. (19 mm) high
Figure 3
1.2 in.
(30.0mm)
1.2 in.
(30.0 mm)
4.8 in.
(122.0 mm)
3.5 in.
(90.0 mm)
unit from hanging from the top
flange, see figure 3 for dimen-
sions.
4. The unit is equipped with a
power supply plug, the plug
should be plugged
a 15 A, 120 V outlet.
Exit for Cord
5.4 in.
(137.0 mm)
3.1 in.
(80.0 mm)
FRONT
directly into
7

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dfi400cCdfi400cDfi600rDfi600cCdfi600l

Table of Contents