Dimplex DFI400LH Service Manual

Dimplex DFI400LH Service Manual

Electric fireplace cassette
Hide thumbs Also See for DFI400LH:

Advertisement

IMPORTANT SAFETY INFORMATION: Always read this manual first before attempting to service this cassette. For your
safety, always comply with all warnings and safety instructions contained in this manual to prevent personal injury or prop-
erty damage.
Dimplex North America Limited
1367 Industrial Road Cambridge ON Canada N1R 7G8
1-888-346-7539 www.dimplex.com
In keeping with our policy of continuous product development, we reserve the right to make changes without notice.
© 2013 Dimplex North America Limited
Service Manual
Model
DFI400LH
DFI400RH
DFI600LH
Part Number
6909050141
6909050142
6909050161
REV
PCN
DATE
00
-
11-OCT-13
7400750000R00

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DFI400LH and is the answer not in the manual?

Questions and answers

Summary of Contents for Dimplex DFI400LH

  • Page 1 Dimplex North America Limited 1367 Industrial Road Cambridge ON Canada N1R 7G8 11-OCT-13 1-888-346-7539 www.dimplex.com In keeping with our policy of continuous product development, we reserve the right to make changes without notice. © 2013 Dimplex North America Limited 7400750000R00...
  • Page 2: Table Of Contents

    NOTE: Procedures and techniques that are considered important enough to emphasize. CAUTION: Procedures and techniques which, if not carefully followed, will result in damage to the equipment. WARNING: Procedures and techniques which, if not carefully followed, will expose the user to the risk of fire, serious injury, or death. www.dimplex.com...
  • Page 3: Operation

    This is normal and should not be a cause for con- * Only applicable when the Dimplex heater has been cern. plugged into the receptacle.
  • Page 4: Maintenance

    Except for installation and cleaning described in this manu- al, an authorized service representative should perform any Light bulb requirement: 45W, 12VAC halogen bulbs type other servicing. MR 16. Contact Dimplex Technical Service at 1-888-346- 7539 for replacement bulbs. Figure 3 Cover...
  • Page 5: Exploded Parts Diagram

    18. 3-Position Switch ....9600383600RP 5. Log Set Assembly - DFI400LH ..9600720100RP - DFI600LH ..9600730100RP 19.
  • Page 6: Wiring Diagram

    WIRING DIAGRAM www.dimplex.com...
  • Page 7: Remote Control Receiver Replacement

    REMOTE CONTROL RECEIVER Figure 4 REPLACEMENT Tools Required: Philips head screwdriver Flat Head Screwdriver Transformers WARNING: Disconnect power before attempting any maintenance to reduce the risk of electric shock or damage to persons. NOTE: Ensure that all of the components that contain water have been emptied before performing any maintenance.
  • Page 8: Thermostat Replacement

    NOTE: The unit will not need to be disassembled to 4. Loosen the securing nut, to allow the potentiometers replace the fuse only. slide out. 5. Reassemble in the reverse order as above. 5. Disconnect the wiring connections noting their original locations. www.dimplex.com...
  • Page 9: Light Assembly Replacement

    LIGHT ASSEMBLY REPLACEMENT Figure 5 Tools Required: Philips head screwdriver Flat Head Screwdriver WARNING: Disconnect power before attempting any maintenance to reduce the risk of electric shock or damage to persons. NOTE: Ensure that all of the components that contain water have been emptied before performing any maintenance.
  • Page 10: Troubleshooting Guide

    Normal Operation Normal operation is when the heater emits an odor for a brief period after the heater is initially turned on. The heater is burning off any dust accumulated during manufacturing or operation. Defective Heater Assembly Replace Heater Assembly www.dimplex.com...