TROUBLESHOOTING

DISPLAY PROBLEMS

If the display does not illuminate
Check connection to the battery.
Battery may be too low to power the analyzer (below 1 volt). Fully
charge the battery and retest.
Internal 9-volt battery may need to be replaced. Replace the 9-volt
battery and retest.
If the analyzer detects computer or ignition noise, a SYSTEM NOISE
message will appear on the display. Verify that all vehicle accessory
loads are off and the ignition switch is in the off position. The ana-
lyzer will automatically retest when the system noise is no longer
detected. If the SYSTEM NOISE message continues after several
retest attempts, disconnect the battery cables and retest.
If the analyzer does not power up when the PRINT/VIEW button is
pressed, replace the 9-volt battery.

PRINTING PROBLEMS

Status LED

When a printer fault occurs, the STATUS LED will flash. You can identify
the fault by the number of sequential flashes:
Sequence
*
*
*
** ** **
*** *** ***
Condition
Paper out
Thermal head too hot
Battery low
12
Solution
Fit new paper
Allow head to cool
Recharge printer
battery for 16 hours