When this screen is active the outputs cannot be changed. By pressing "V", the controller will go
into "Override" mode. The screen will then look like this:
When this screen is active, pressing A,B,D,E,F,G,H,I will change the state of the output relays. To
raise/lower the squeegee both the A and B outputs must change. As indicated on the first line,
pressing "S" will raise/lower the squeegee (This actually is changing A and B simultaneously).
Finally, there is a number to the right of the equal sign as shown here:
a b = d e f g h i
This number is the number of amps that the brush motors are actually drawing in real time.
The line below would be 52 amps being drawn by the brush motors.
a b = d e f g h i
Minuteman PowerBoss Inc. Copyright 2000
MAINT MODE
OVERRRIDE MODE S=SQ UP/DN
a b = d e f g h i
I Chms
H Syst
G Brsh
F VacM
E Wtrs
D Multi
B Sq-
A Sq+
j k l m n o - - r =
j k l m n o - - r =
Operation, Maintenance & Troubleshooting
j k l m n o - - r =
R SolE
O Recy
N TkFl
M OffA
L Rev
K Fwd
J SysR
0
52
16
0
3800 Rider Scrubber (7/02)