F277Y800-03
Example Part Number:
F__ __ __
__
__ __ __ __
Nominal
Voltage Codes
120
120V
208
208V
220
220V
230
230V
240
240V
277
277V
480
480V
600
600V
Source configuration
N
1 Phase L-N 2w + gnd
L
1 Phase L-L 2w + gnd
S
Split Phase 3w + gnd
Y
3 Phase Wye 4w + gnd
D
3 Phase Delta 3w + gnd
H
3 Phase Delta Hi-leg 4w+ gnd
Current
Current
Code
Rating
30
30A
60
60A
100
100A
225
225A
400
400A
800
800A
1200
1200A
2000
2000A
4000
4000A
* 200kA is available,
add –200 to part number.
Job Name____________________________
Model# ______________________________
Date ________________________________
Qty _________________________________
Quote# ______________________________
Liebert Corporation • 1050 Dearborn Drive • PO Box 29186 • Columbus, OH 43229
Phone 607-724-2484 • Fax 607-722-8713 • US & Canada 800-288-6169
EMAIL: info@control-concepts.com • Web Site: www.Liebert.com
Operating Voltage Range ......................................... +/-15%
Fault Current Rating (AIC)........................................ 200 kAIC
Operating Frequency Range.................................... 47 – 63 Hz
50
EMI/RFI Attenuation:
Response Time ......................................................... <0.5 ns
Operating Humidity................................................... 0% to 95%
Status Indication ....................................................... LEDs, Dry Contacts, Audible Alarm,
Certifications ............................................................. UL 1449 & 1283, CSA
Enclosure .................................................................. NEMA 12 standard
Warranty .................................................................... 10-Years Parts / 5-Years Labor
Optional Equipment.................................................. Dual Surge Counter,
= 277/480V, 3-Phase Wye, All Mode, 800 Amp Current Rating
LED's, Alarm & Dual Counters, Form C Contacts
- __ __
Option Code
LED, Form C
01
LED, Alarm, Dual
03
Counters, Form C
LED, Alarm, Counter,
06
Form C Contacts
Surge Current Capability
Per Phase
100kA
100kA
150kA
150kA
150kA
300kA*
300kA*
300kA*
300kA
Liebert Active Tracking Filter System
Technical Specification
Normal Mode .............................................. 10 kHz-500MHz 60 dB
Common Mode ........................................... 10 kHz-500MHz 50 dB
Unit
100 kA
150 kA
200 kA
300 kA
Contacts
Contacts
Voltage
100-120V
208V
230-277V
347V
400-480V
600V
Dimensional data in inches and shipping weight in pounds
Model/Configuration
30A Single Phase
30A Split or Three Phase
60A Single Phase
60A Split or Three Phase
100A Single Phase
100A Split or Three Phase
225A Single Phase
225A Split or Three Phase
400A Split or Three Phase
800A Split or Three Phase
1200A Split or Three Phase
2000A Split or Three Phase
4000A Split or Three Phase
Surge Counter
Remote Monitor Panel
Life Cycle Surge Testing
10kA, 20kV, IEEE Cat. C3
Per Mode (L-N/L-G/N-G)
12,000/12,000/12,000
12,000/24,000/24,000
24,000/24,000/24,000
24,000/48,000/48,000
UL 1449 second edition clamping data
L-N
L-G
L-L
400
400
800
800
800
800
800
1500
1200
1000
2000
1500
1500
2000
2000
Dimensions in inches
A
B
C
D
E
20.0
16.0
9.0
21.25
10.0
24.0
20.0
9.0
25.25
14.0
20.0
16.0
9.0
21.25
10.0
24.0
20.0
9.0
25.25
14.0
24.0
20.0
9.0
25.25
14.0
30.0
24.0
9.0
31.25
18.0
24.0
20.0
9.0
25.25
14.0
30.0
24.0
9.0
31.25
18.0
48.0
36.0
12.0
49.25
30.0
60.0
48.0
12.0
-
-
60.0
48.0
20.0
-
-
60.0
48.0
20.0
-
-
60.0
48.0
20.0
-
-
Per Phase
24,000
36,000
48,000
72,000
N-G
400
700
1000
Wt
F
Lbs
.44
35
.44
60
.44
35
.44
60
.44
60
.44
80
.44
60
.44
80
.44
300
-
530
-
750
-
950
-
1300
82245 Rev 0
Need help?
Do you have a question about the F277Y800-03 and is the answer not in the manual?