Standard Features; Dial Thermometer; Optional Features - Liebert Process Fluid Chiller PS024A Specification Sheet

Process fluid chiller designed for varian clinac 4/100, 6/100 & 600c

Advertisement

OPTIONAL REFRIGERANT
PRESSURE GAUGES
SHADED AREAS
RECOMMENDED CLEARANCE
FOR COMPONENT REMOVAL,
ACCESS, AND AIR FLOW.
I
H
1" NPT
A-Depth
Model No.
in. (mm)
PS018A
36 (914)
PS024A
36 (914)
PS036A
36 (914)
PS048A
36 (914)
PS060A
36 (914)

Standard Features

• Indoor/outdoor cabinet
• Hermetic compressor
• Refrigerant dehydrator
• Expansion valve
• Refrigerant receiver
• Stainless steel fluid reservoir expansion tank
• Pressure relief valve
• Hot gas bypass valve capacity control

Optional Features

• Refrigerant gauges and reservoir heater
• Stainless steel pump
1050 Dearborn Drive
P.O. Box 29186
Columbus, OH 43229
Phone: 800.877.9222
Fax: 614.841.6022
Liebert Web Site—http://www.liebert.com
SL-16548 (07/00)
AIRFLOW
IN
C*
2"
18"
(51mm)
(457mm)
INDICATE A
I
H
UNIT DIMENSIONAL DATA
1" MAX.
1" MAX.
(25mm)
(25mm)
B-Width
C-Height
in. (mm)
in. (mm)
40 (1016)
25.25 (641))
40 (1016)
25.25 (641)
48 (1219)
32.5 (825)
53 (1346)
38.5 (978)
53 (1346)
38.5 (978)
Via Leonardo Da Vinci 8
Zona Industriale Tognana
35028 Piove Di Sacco
Italy
Phone: 39.049.9719.111
Fax: 39.049.5841257
Process Fluid Chiller Designed For Varian CLINAC 4/100, 6/100 & 600C
A
B
D
36"
(914mm)
36"
(914mm)
UNIT DIMENSIONAL DATA
Weight
Voltage
lbs. (kg)
(60 Hz)
394 (178)
208/230, 1-phase
404 (183)
208/230, 1-phase
515 (233)
460, 3-phase
208/230, 1- or 3-phase
592 (268)
460, 3-phase
208/230, 3-phase
642 (291)
460, 3-phase
208/230, 3-phase
Accessories
• Emergency water bypass
• Enviro-source emergency bypass
• Water level control and alarm system
• Fluid pressure gauge
• Check valve

• Dial thermometer

• Relief valve
• Circuit setter
• Ball valve
• High temperature thermostat
• Low flow switch
• Liebert RCM8 monitor
23/F Allied Kajima Bldg.
138 Gloucester Road
Wanchai
Hong Kong
Phone: 852.2.572.2201
Fax: 852.2.572.1182
AIRFLOW
OUT
SHADED AREAS
INDICATE A
RECOMMENDED CLEARANCE
FOR COMPONENT REMOVAL,
ACCESS, AND AIR FLOW.
36"
(914mm)
Voltage
(50 Hz)
200/230, 1-phase
200/230, 1-phase
400, 3-phase
200/230, 1- or 3-phase
400, 3-phase
200/230, 1- or 3-phase
400, 3-phase
200/230, 1- or 3-phase
©2000 Liebert Corporation. All rights
reserved throughout the world.
Specifications subject to change without
notice.
®Liebert and the Liebert logo are
registered trademarks of Liebert
Corporation. All names referred to are
trademarks or regisered trademarks of
their respective owners.
2

Advertisement

loading

This manual is also suitable for:

Ps018aPs036aPs048aPs060a