CONTROLS SPECIFICATION
AUTO FAN SPEED
In cool mode, if Tr-Ts < 0 , indoor fan is run at low speed.
Tr-Ts
In heat mode, if Tr-Ts < 1 , indoor fan is run at low speed.
Tr-Ts
MANUAL SWING (STEPPING MOTOR)
If the indoor fan is operating, the louver will swing or can be stopped at a preferred
location in any mode. The louver change location follow the order of :
BUZZER
If a command is received, the system will respond with a beep.
7 7
C
If 0
C
<Tr-Ts<2
C
no change in speed , if fan is running at medium speed ,there will be
no change in speed ,if indoor fan is run at high speed ,it will change
to medium speed.
If 2
C
<Tr-Ts<4
C
C
If Tr-Ts>4
indoor fan is run at high speed.
MEDIUM SPEED
LOW SPEED
0
C
C
If 1
C
<Tr-Ts<3
C
change in speed , if fan run at medium speed ,there will be no change
in speed , if indoor fan is run at high speed ,will change to medium
Speed.
C
If 3
<Tr-Ts<5 indoor fan keep original speed.
C
If Tr-Ts>5
indoor fan is run at high speed.
C
MEDIUM SPEED
LOW SPEED
0
C
, if indoor fan is running at low speed, there will be
indoor fan keep original speed.
2 C
4 C
, if indoor fan is run at low speed, there will be no
2 C
4 C
HIGH SPEED
HIGH SPEED