White Mountain Hearth DVX36FP32CLN-1 Installation Instructions And Owner's Manual page 23

The tahoe direct vent zero clearance gas fireplace heater
Hide thumbs Also See for DVX36FP32CLN-1:
Table of Contents

Advertisement

DVVK-4FV DIRECT VENT TERMINATION KIT (cont.)
1.
Unpack vent components and check all items for shipping
damage.
2.
For this venting system to operate as designed it is depen-
dent on the use of all parts and procedures detailed in these
instructions. Failure to follow these instructions may poten-
tially affect the performance of this vent system and the at-
tached appliance.
3.
As per the fireplace manufacturer's instructions, replace the
existing 6 5/8" diameter fireplace vent adapter with the 7"
diameter flex vent fireplace adapter included in the vent kit.
Install the adapter collar with the screws removed from the
standard fireplace collar. Refer to the fireplace manual for ad-
ditional information on the vent collar removal and installa-
tion.
4.
Once the fireplace location has been determined, mark the
ceiling where the flex vent will pass through. Cut an opening
for installation of the firestop thimble assembly. The open-
ing must measure a minimum of 9-1/2" x 9-1/2" square. See
Figure 32.
FIRESTOP
THIMBLE
25047-0-0309
Step-By-Step Installation For Flex DV Kit
CEILING FRAMING
9 1/2" Min.
(241mm)
NOTE: ADDITIONAL
HOLES FOR ADJUSTING
THIMBLE UP OR DOWN
AS NEEDED
NAILS
(4) REQ'D
Figure 32
5. Next, determine the location for the cutout in the roof open-
ing. This opening must be large enough to provide a mini-
mum 1" air space clearance from the vertical vent pipe to any
combustible framing.
6. Install the Firestop/Thimble assembly to the framed opening
in the ceiling using common nails or screws.
Note: The thimble assembly is adjustable up or down as
needed within the firestop. It is also designed with a pivoting
firestop for use with 0 - 3/12 pitch cathedral ceilings.
7. To begin vent system assembly, first layout all the vent com-
ponents on the floor in the order in which they will be as-
sembled.
8. Stretch the 4" diameter inner flex flue and 7" diameter outer
flex vent to the maximum length of 6 feet.
9. Install the spring spacers provided around the 4" diameter
flex flue at 1 foot intervals, then slide the flue pipe with spac-
ers into the 7" diameter outer flex vent pipe. Make sure the
springs are spaced evenly starting at 12 inches from the fire-
place collar. See Figure 33.
FLEX OUTER
AIR INTAKE PIPE
12"
12"
305mm
305mm
4" FLEX
VENT PIPE
Figure 33
SPACER SPRINGS
FLEX FLUE PIPE
12"
12"
305mm
305mm
SPACER SPRINS
Page 23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents