17. Faults

Fault Diagnosis

The list of possible faults and the appropriate trouble shooting is divided into two main groups:
- Faults which are not indicated in Display
- Faults which are indicated as messages in Display

Errors not indicated in Display

Fault
No function, no display
Noise from the brewer
Drinks too cold

Error messages in Display

Fault
Door open !
Insert cup
Possible cause
Main switch defective
Power supply interrupted
Cable harness defective
Electronic control defective
Plug contact fault
Fuse defective
Brewer tacho defective
Contact fault
Cable harness defective
Mechanical defect
Water supply too cold
Temperature sensor is
maladjusted
Possible cause
Door not closed properly
Door switch defective
Door harness defective
No cup located on cup
platform
Defective cup sensor
Remedy
Check the main switch, replace it if neces-
sary
Check the power supply
Check the fuse in the power supply unit,
replace it if necessary
Check the power supply cable, replace it if
necessary
Replace the cable harness
Replace the electronic control
Check contacts, replace if necessary
Check the power supply, replace the fuse
if necessary
Check the brewer tacho, replace it if nec-
essary
Check the contacts (check cable harness
for conductivity)
Check the cable harness, replace it if nec-
essary
Check actuator, replace it if necessary
Raise temperature
Check and adjust temperature setting
Remedy
Close door properly
Check, replace if necessary
Check, replace if necessary
Place cup on cup platform
Check, replace if necessary