Draining The Boiler; Small Technical Maintenance - ECM Barista A2 User Manual

Hide thumbs Also See for Barista A2:
Table of Contents

Advertisement

Available languages

Available languages

8
Afterwards, unclamp the porta filter, take out the blind filter and reinsert the coffee filter into the porta filter.
Clamp the porta filter back into the brew group.
Caution!
Beware of hot water sprayings while cleaning the brew group.

7.3 Draining the boiler

1
Turn the machine off and let it cool down.
2
Remove the drip tray.
3
Open the hot water valve (caution: hot water may spray).
4
The water is released through the collection container through the drainage hose.
5
The boiler is empty once no more water is shown in the water level indicator.
6
Close the hot water valve.

7.4 Small technical maintenance

(If you have any questions, please contact your specialised dealer.)
Replacing the group gasket and the shower screen (Group gasket (item no. C449900229) and shower screen (item
no. C519900103) must be changed at the same time)
1
Switch the machine off and let it cool to room temperature.
Follow the steps as indicated below:
1
Brew group in the beginning.
4
Remove the shower screen and the
gasket completely.
2
Use a flat screwdriver to pry out the
shower screen and the group gasket.
5
Keep the new spare parts ready at
hand (the rounded side of the group
facing upwards to the brew group).
23
3
The shower screen and the gasket are
now nearly removed.
6
Clean the brew group with a brush.
Lock the shower screen firmly into
the gasket.