WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION
MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
A. this appliance has a pilot which must be lighted with a piezo
igniter. When lighting the pilot, follow these instructions
exactly.
B. BEFORE OPERATING smell all around the appliance area for
gas. Be sure to smell next to the floor because some gas is
heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Extinguish any open flame.
• Open windows.
• Do not light any appliance.
• Do not touch any electrical switches.
1. STOP! read the safety information above on this page.
2. access the lower control compartment.
3. turn remote wall switch to "oFF."
4. Verify main line shut-off valve is open.
5. Push in gas control knob slightly and turn clockwise
to "oFF."
Note: Knob cannot be turned from "PILOT" to "OFF"
unless the knob is pushed in slightly. Do not force.
1. turn remote wall switch "oFF." the pilot will remain lit for
normal service.
2. For complete shutdown, turn remote wall switch to "oFF."
3. access the lower control compartment.
LIGHTING INSTRUCTIONS – MILLIVOLT
FOR YOUR SAFETY READ BEFORE LIGHTING
LIGHTING INSTRUCTIONS
OUT
IN
TO TURN OFF GAS TO APPLIANCE
• Do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's
phone.
• If your gas supplier cannot be reached, call the fire depart-
ment.
C. use only your hand to push in or turn the gas control knob.
Never use tools. if the knob will not push in or turn by hand,
do not try to repair it, call a qualified service technician. Force
or attempted repair may result in a fire or an explosion.
D. Do not use this appliance if any part has been under water.
immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which has been under water.
6. Wait five (5) minutes to clear out any gas. if you then smell
gas, stoP! Follow "B" in the safety information above on
this page. if you do not smell gas, go to the next step.
7. Push in gas control knob slightly and turn counterclockwise
to "Pilot."
8. Push in control knob all the way and hold in. immediately
light the pilot by triggering the spark igniter (pushing the
button) until pilot lights. continue to hold the control knob
in for about 1-1/ minutes after the pilot is lit. release knob
and it will pop back up. Pilot should remain lit. if it goes out,
repeat steps 5 through 8.
• if knob does not pop up when released,
stop and immediately call your service
technician or gas supplier.
• if pilot will not stay lit after several tries,
turn the control knob to "oFF" and call
your service technician or gas supplier.
9. turn gas control knob counterclockwise
10. close lower control compartment.
4. Depress gas control knob slightly and turn clockwise
to "oFF." Do not force.
5. close lower control compartment.
to "oN."