CAUTION: Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
If any of the original wire as supplied must be replaced, it must be replaced
with Type AWM 105°C – 18 GA. wire.
OPTIONAL
REMOTE CONTROL
(MILLIVOLT)
Figure 22 - Millivolt Wiring Diagram
Model No.
BTU/HR
Input
LSVFSD-NG
37,000
24,500
LSVFSD-LP
37,000
28,000
Table 3
16
MILLIVOLT VALVE
Vented/Unvented Gas Log Appliance Technical Chart For Millivolt Log Set
Gas Type
Ignition
Regulator
Pressure Setting
Natural
Piezo
1.6 – .5" W.c.
Propane/
Piezo
6. – 10.0" W.c.
lPg
* For the purpose of input adjustment.
Note: Diagrams aND illustratioNs are Not to scale.
PILOT (O.D.S.)
ASSEMBLY
WHITE
RED
WHITE
WHITE
ON/OFF
SWITCH
PILOT PIEZO
IGNITER
Gas Inlet
Valve
Pressure*
Operation
max. 10.5" W.c.
millivolt
min. 5.0" W.c.
max. 1" W.c.
millivolt
min. 11" W.c.
IGNITION
WIRE
Orifice Size
Orifice Size
Air Shutter
Top
Bottom
Opening
.094"
.071"
.055"
.046"
1/8"
1/4"

Hide quick links: