  • Page 1: Safety Instructions

    ECOPOD-N Series ™ Fixed Film Wastewater Treatment System P.O. BOX 969, DENHAM SPRINGS, LA 70727 Safety Instructions (225) 665-6162 – Telephone (225) 664-9467 – Fax Installation and Service Manual K4509 11/09...
  • Page 2 INTRODUCTION A WORD ABOUT YOUR DELTA ECOPOD-N DESCRIPTION ™ ADVANCED WASTEWATER TREATMENT Wastewater enters a pretreatment/settling tank similar to SYSTEM AND HOW IT WORKS conventional septic tanks. In this tank, debris and settleable solids settle to the bottom and are decomposed by anaerobic The ECOPOD-N Fixed Film Wastewater Treatment System ™...
  • Page 3 For anything other than domestic wastewater Every 3 Months: The air filter on the air pump should be contact Delta Environmental Products. cleaned. Rinse with warm water if necessary. (See installation instructions). Do not use oil or other solvents.
  • Page 4: Solids Removal

    Refer to the Installation Instructions to get the treatment plant conjunction with equipment manufactured by Delta back into operation. Environmental Products. Delta Environmental Products Should indication of improper operation be observed at any point is not responsible for the mechanical or electrical safety in time, contact your local distributor.
  • Page 5: Sample Requirements

    Seasonal Use Guidelines Of ECOPOD-N ™ Biochemical Oxygen Demand (BOD) Fixed Film Wastewater Treatment System Samples for BOD analysis may degrade significantly during storage between collection and analysis, resulting in low BOD These guidelines are for conditions as outlined below and apply values.
  • Page 6: Delivery Inspection

    Upon are missing. Also inspect for damage to the unit. If any receiving the unit, please follow this procedure. discrepancies are found, notify Delta Environmental Products at 1-800-219-9234 Before unpacking, check the packaging for signs of damage.
  • Page 7: Installation

    INSTALLATION Prepare an excavation, having a diameter approximately 10. After the control panel is properly mounted, connect conduit one foot larger than the tank and a depth that will allow and install wiring as shown on drawings bound herein. approximately three inches of the inspection port to extend 11.
  • Page 8: Trouble Shooting Electrical System

    TROUBLESHOOTING GUIDE FOR DELTA Improper Installation Or Settling ECOPOD-N FIXED FILM WASTEWATER ™ You should follow the manufacturer installation procedures TREATMENT SYSTEM very carefully. Where settling is common, approximately 2 inches of sand should be placed and tamped in the bottom of the hole. Procedure for Visual and Olfactory Proper installation is the first step in preventing call backs for Evaluation of System...
  • Page 9: Component Replacement Procedure

    Component Replacement Procedure General Comments Air Pump – Follow same procedure as outlined in the “Instal- Only factory approved equipment can be used for replace- lation Instructions”. ment on individual treatment systems. Float Switch – Remove Treatment Plant’s Riser or 24 inch If the decision is made to pump out a system, be sure to cover.
  • Page 10: Electrical Requirements

    Electrical Requirements Model Compressor Motor full load Amps Measured Operating Watts Electrical Requirements E50-N Delta Model E50 115 volt - single phase E60-N Delta Model E60 115 volt - single phase E75-N Delta Model E75 115 volt - single phase E100-N Delta Model E100 115 volt - single phase...
  • Page 11 Replacement parts or components may be obtained from your local distributor or directly from Delta Environmental Products. COMPLAINTS: In order for Delta Environmental Products to properly address complaints, we require that you put in writing the date and nature of the complaint as detailed as possible. This must include the Serial Number of your system.
  • Page 12: Limited Warranty

    LIMITED WARRANTY Delta Environmental Products warrants the parts in each treatment system for a limited two (2) years. All warranty questions shall be resolved through Delta Environmental Products. The warranty on the treatment device is that the device is free from defects in material and workmanship from the date of installation treating household wastewater.