LAMP CONTROL - Lamp ON/OFF
When ON, manual control of lamp power can be accessed via system menu.
LAMP CONTROL - Automatic Lamp ON
When ON, lamp is automatically powered ON when power is applied to fixture.
LAMP CONTROL - Lamp ON via DMX
When ON, lamp can be powered ON via a DMX controller.
LAMP CONTROL - Lamp OFF via DMX
When ON, lamp can be powered OFF via a DMX controller.
LAMP CONTROL - Max ON at Temp
The fixture is designed to shut the lamp OFF when an excessive temperature is
sensed inside the head by the on-board CPU. The lamp is shut OFF to prevent
damage to the lamp and avoid possible internal damage to the fixture head.
This function sets the MIN internal operating temperature of the fixture head before
the lamp will restrike after the lamp has been automatically shut OFF.
LAMP CONTROL - Lamp OFF Temp
The fixture is designed to shut the lamp OFF when an excessive temperature is
sensed inside the head by the on-board CPU. The lamp is shut OFF to prevent
damage to the lamp and avoid possible internal damage to the fixture head.
This function sets the MAX internal operating temperature of the fixture head when
the lamp will automatically be shut OFF.
PERSONALITY - Status Settings - Address Via DMX
When ON, define the desired DMX address via an external controller.
1. Connect the fixture to the external controller and power ON.
2. Set the DMX value of Channel 1 on the controller to (7).
3. Set the DMX value of Channel 2 on the controller to (7) or (8).
When set to (7), the DMX address can be set between (1) and (255).
When set to (8), the DMX address can be set between (256) and (511).
4. Using Channel 3 on the controller set the desired DMX address of the fixture.