Aritech 1200C User Manual
Aritech 1200C User Manual

Aritech 1200C User Manual

Fire alarm control panel and repeater

Advertisement

1200C-2000C Fire Alarm
Control Panel and
Repeater User Manual
P/N 10-3311-505-1003-01 • ISS 18DEC14

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1200C and is the answer not in the manual?

Questions and answers

Summary of Contents for Aritech 1200C

  • Page 1 1200C-2000C Fire Alarm Control Panel and Repeater User Manual P/N 10-3311-505-1003-01 • ISS 18DEC14...
  • Page 2 Copyright © 2014 UTC Fire & Security. All rights reserved. Trademarks and The 1200C-2000C name and logo are trademarks of patents UTC Fire & Security. Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products.
  • Page 3: Table Of Contents

    Panel operation in standby 11 Panel operation in fire alarm 12 Panel operation in pre-warning 13 Panel operation in fault 14 Maintenance 15 Fire alarm system maintenance 15 Battery maintenance 16 Product Compliance 17 1200C-2000C Fire Alarm Control Panel and Repeater User Manual...
  • Page 4: Important Information

    Important information Introduction This is the installation manual for UTC Fire & Security 1200C-2000C addressable fire alarm control panels and repeaters. Read these instructions and all related documentation entirely before operating this product. Product compatibility All models are compatible with UTC Fire & Security Aritech fire detectors and manual call points.
  • Page 5: Controls And Indicators

    6. Repeater buttons and indicators 2. Alphanumeric keypad 7. Controls buttons and indicators 3. Fire brigade buttons and indicators 8. Zone indicators 4. Key switch 9. General indicators 5. Sounder buttons and indicators 1200C-2000C Fire Alarm Control Panel and Repeater User Manual...
  • Page 6: User Interface Controls

    "MORE" prompt appears on the LCD screen. Exit a menu Enter or confirm a value or selection Move to the next field on the LCD screen Move to the previous field on the LCD screen 1200C-2000C Fire Alarm Control Panel and Repeater User Manual...
  • Page 7 Button Description Increase a value Decrease a value 1200C-2000C Fire Alarm Control Panel and Repeater User Manual...
  • Page 8: General Indicators

    A yellow LED indicates one or more of the following general faults: • Device fault· • Supply fault • Processor fault • Bell fault • Communications fault • Fire brigade fault· • Any test mode· • Any disablement 1200C-2000C Fire Alarm Control Panel and Repeater User Manual...
  • Page 9 FEP fault • Repeater down • Watchdog time-out Processor running A flashing green LED indicates normal operation Supply on A steady green LED indicates that the control panel is powered up 1200C-2000C Fire Alarm Control Panel and Repeater User Manual...
  • Page 10: Controls Buttons And Indicators

    Test Third Source Enabled or disabled Press this button to test the third source battery. The yellow LED is steady and the internal buzzer sounds intermittently. 1200C-2000C Fire Alarm Control Panel and Repeater User Manual...
  • Page 11: Sounder Buttons And Indicators

    Silence Enabled A yellow LED indicates that the sounders have been silenced. Note: Functionality of the Sound and Silence buttons is defined by the control panel operating mode. 1200C-2000C Fire Alarm Control Panel and Repeater User Manual...
  • Page 12: Fire Brigade Buttons And Indicators

    Push this button to stop the fire brigade notification A yellow LED indicates that the signal has been stopped. Note: Functionality of the Signal and Stop Fire Brigade buttons is defined by the control panel operating mode. 1200C-2000C Fire Alarm Control Panel and Repeater User Manual...
  • Page 13: Repeater Buttons And Indicators

    Press this button for the global repeater panel to send a command to all control panels that the global repeater communicates with. The command from the next command button to be pressed is then sent to all corresponding panels. 1200C-2000C Fire Alarm Control Panel and Repeater User Manual...
  • Page 14: Zone Indicators

    LED indicates a fault. The zone fault LED flashes when there is a fault and remains steady if the entire zone has been disabled. Figure 7: Zone fire and fault indicators 1200C-2000C Fire Alarm Control Panel and Repeater User Manual...
  • Page 15: Operation

    5. System status. The current number of fire alarms, faults, and conditions are displayed here as well as repeater information (P is global with panel number shown, L is local) and a summary of the operations (eg, SDZ). 1200C-2000C Fire Alarm Control Panel and Repeater User Manual...
  • Page 16: Panel Operation In Fire Alarm

    If the fire alarm continues, then one of the following is true: • The fire is not under control (perform the above checks again). • The cover glass of a manual call point is broken (repair or disable the manual call point). 1200C-2000C Fire Alarm Control Panel and Repeater User Manual...
  • Page 17: Panel Operation In Pre-Warning

    If the pre-warning continues, then one of the following is true: • The event is not under control (return step 3 above). • The detectors are contaminated with smoke (clean the detectors). 1200C-2000C Fire Alarm Control Panel and Repeater User Manual...
  • Page 18: Panel Operation In Fault

    Event: 79 Active Zone: 6 Area: 1 ALMLVL Address: 1/12 Communication fault 06/02/05 09:39:34 (Site text – up to 40 characters)  X Alarm: 0 Faults: 1 Cond.: 0 P: 1 SDZ 1200C-2000C Fire Alarm Control Panel and Repeater User Manual...
  • Page 19: Maintenance

    • Visually inspect the manual call points, detectors, and sounders to ensure that no structural or occupancy changes have affected their location requirements. 1200C-2000C Fire Alarm Control Panel and Repeater User Manual...
  • Page 20: Battery Maintenance

    2. Install and connect the replacement batteries using the bridge provided. Observe correct polarity. Always use the recommended replacement batteries. Dispose of used batteries according the European regulations and/or instructions from local authorities. 1200C-2000C Fire Alarm Control Panel and Repeater User Manual...
  • Page 21: Product Compliance

    Product Compliance All 1200C-2000C control panels are designed to comply with the requirements of European standards EN 54-2 for control and indicating equipment, and EN 54-4 for power supply equipment). EN 54-2 compliance for control panels with the SD2000 module...
  • Page 22 Declaration of Performance 360-3315-0299 number EN 54 EN 54-2:1997+A1:2006 EN 54-4:1997+A1:2002+A2:2006 Product identification See model number on product identification label Intended use See DoP point 3 Essential characteristics See DoP point 9 1200C-2000C Fire Alarm Control Panel and Repeater User Manual...

This manual is also suitable for:

2000c

Table of Contents