5.8.5

Welding data display

The following welding parameters can be displayed before (nominal values) or during (actual values)
welding.
Parameter
Welding current
Welding voltage
JOB number
Parameter times
Parameter currents
5.8.5.1

Welding parameter setting

The parameters that can be set in the function sequence of the machine control depend on the selected
welding task. This means that if for example you have not selected a pulse variant, then you cannot set
any pulse times in the function sequence.
5.8.5.2

Welding current display (ignition, secondary, end and hotstart currents)

The welding currents for secondary current, ignition current and end current (expert menu) can be
displayed as percentages (factory setting) or absolute values on the machine display.
ENTER
0
l
Display
099-000117-EW501
26.08.2014
Before welding
(nominal values)
+
Setting/selection
Exit the menu
Exit
Machine configuration
Settings for machine functions and parameter display
Welding current display (ignition, secondary, end and hotstart currents)
Pro = welding current display as a percentage of the main current (factory setting)
Abs = absolute welding current display
During welding
(actual values)
EXIT
Figure 5-9