Support - Regular Ceiling:
19" width x 17" depth (480 x 432 mm)
Joist or Roof
Truss
1/2" (12 mm)
Mandatory
2" (50 mm)
Minimum
Air Space
Female Chimney
End
Fireplace Hood
(presoldered
to the ceiling
adaptor)
17" (432 mm)
Wall Finish: Gypsum
board, wood or plywood mandatory
DRAWING 7
7.3 Diameter of the hole for the chimney
passage:
.1 Combustible wall: If your wall is made
out of combustible materials (gypsum board,
wood, insulation, etc), drill a hole at least 4"
(100 mm) more in diameter than the
chimney's exterior diameter to permit the
passage of the chimney plus its mandatory 2"
(50 mm) minimum air space.
shield/firestop must also be installed around
the chimney where the chimney passes
through the wall.
available to conceal the empty space around
the chimney.
.2 Incombustible wall : If you are working
with a 100% incombustible wall
co nc re te fo un da ti on wa ll wi th ou t a
combustible finish), drill a hole of a diameter
sufficient to allow for the passage of the
REV. 2014-11
Dust/Radiation Shield
Joist or Roof
Truss
Factory-built
Chimney
8" I.D.
(200 mm)
C
8" (200 mm)
A radiation
A decorative collar is
Support - Cathedral Ceiling:
17" width x 16" depth (432 x 407 mm)
Decorative
Collar - 3"
(76 mm)
Cathedral
Adaptor
Fireplace Hood
(presoldered
to the cathedral
adaptor)
DRAWING 8
chimney. Gypsum boards are considered
combustible materials and any wall that
contains them is considered a combustible
wall. (See the previous article).

8. Chimney - Regular Ceiling

8.1 Regular ceiling adaptor (Drawing 7): The
regular ceiling adaptor is 19" (480 mm) wide by
17" (432 mm) deep. Locate the center of the
chimney at a distance of 8" (200 mm) from the
wall. The diameter of the hole for the chimney
must be sufficient to include the mandatory 2"
(50 mm) minimum air space. Make sure that the
hole does not extend beyond the dimensions of
the ceiling adaptor.
installed before the fireplace, it must project 1/2"
(like a
(12 mm) below the finished ceiling. The ceiling
adaptor has 4 holes for its fixation against the
ceiling. Plan the wood supports required for its
Page 9
rigid rockwool insulation
Factory-built
Chimney
8" I. D.
(200 mm)
C
C
8"
(203 mm)
16" (407 mm) Depth
Wall Finish: Gypsum board,
wood or plywood mandatory
If the chimney must be
Female
Chimney
End

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7007710071207005