Starting A Chimney On A Ceiling Adaptor; Radiation Shield/Firestop; Minimum Chimney Height Above The Roof; Flashing Watertightness - Les Foyers Don-Bar 5005 Installation, Operation And Maintenance Manual

Open fireplaces
Table of Contents

Advertisement

Ceiling adaptor. Offset supports must be installed
above and as close as possible to each offset
(elbow) in the chimney.

10.6 Starting a chimney on a ceiling adaptor:

Install the chimney by slipping the first chimney
section until it reaches the bottom of the ceiling
adaptor. Be sure the chimney fits well into the
ceiling adaptor before proceeding to other
chimney sections.
come in contact with the chimney. Always allow
a 2" (50 mm) minimum air space between the
chimney and adjacent materials.
10.7
Radiation shield/firestop: Install a
radiation shield/firestop every time the chimney
passes through a combustible wall or ceiling.

10.8 Minimum chimney height above the roof

(Drawing no 9): Extend the chimney at least 3
feet (1 m) above the roof or 2 feet (610 mm)
above any construction element within 10 feet (3
m) of the chimney.
10.9 Flashing water tightness: Install a metal
roof flashing with a storm collar where the
chimney meets the roof. Seal the joint between
the chimney and the storm collar and the joint
between the roofing and the flashing.
10.10 Roof braces: Any chimney that extends
more than 6 feet (2 m) above the roof needs to be
laterally strengthened with a pair of telescopic

roof braces.

10.11 Chimney top: Install a chimney round top
at the end of the chimney.

11. Fireplace installation

11.1 Preliminary insertion of the hearth plate

bolt: (Fireplace 7100 only): Before you install
the back heat shield of the 7100 fireplace, insert
the bolt that will retain the inside steel hearth
REV. 2014-11
Never let the attic insulation
plate. It goes in the existing hole at the back of
the fireplace. (Drawing 13).
Fireplaces 7007, 7100, 7120:
Mounting

Heat Shield

Wall Support Bracket
DRAWING 10
11.2 Heat shield: Before installing the fireplace
on its wall support bracket, mount the heat shield
on the back of the fireplace (if it has not already
been installed by the manufacturer). Begin the
installation by fixing the bolt at the top of the
shield.
The heat shield will be retained
automatically by the fireplace bolts on the
bottom.
11.3 Fireplace mounting: Install the fireplace on
the wall support bracket with the three supplied
bolts. First, insert the upper bolt into the wall
bracket then put the fireplace in place. Tighten
the nuts and bolts firmly but without forcing from
the inside of the fireplace. If necessary, use a jack
to raise the fireplace and keep it in place during
the bolting.
Page 11
Factory-built
chimney
8" dia. I.D.
(200 mm)
Solid
Backing
Floor Protection

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7007710071207005