3. Before beginning the installation

3.1 Choosing the best location:

beginning the installation, make sure the spot you
have in mind for the fireplace and the chimney
meet the following requirements:
Typical installation with a wall
outlet
Round Top
Storm Collar
Fireplace
Don-Bar
7007
Floor
Proctection
DRAWING 2
REV. 2014-11
3.2 Chimney: Position the chimney to avoid, as
much as possible, offsets, elbows, and the cutting-
out of structural elements. The weight of the
chimney must not be supported by the
Before
fireplace. Allow at least 2" (50 mm) for air space
between the chimney and any combustible
material including electrical cables and plastic
plumbing pipes. Never fill this air space with
insulation. For example, if the chosen factory-
built chimney has an outside diameter of 10" (250
mm), by adding the required 2" (50 mm) air
space, a minimum 14" (355 mm) free
continuous path is required to install the
Factory-built
chimney. If the fireplace has a ceiling outlet, it is
Insulated Chimney
usually easier to install the fireplace first, then the
8 inches I.D.
(200 mm)

chimney.

chimney connected to another heating device.
Roof Support
3.3 Chimney minimum height: 15 feet (4600
Flashing
mm). This length is measured from the floor
where the fireplace is installed to the top of the
chimney.
Wall
3.4 Minimum clearances from combustible
Band
materials: Position the fireplace (Drawing 3) to
allow for the minimum mandatory clearances
Mandatory
2" minimum
air space
(50 mm)
Fireplace clearances from
Wall
Shield/Firestop
combustible materials
IMPORTANT:
Clearances and floor
protection dimensions
vary with each
fireplace model.
Consult the chart
specific to your
Wall Support
fireplace:
5005: Page 16
7005: Page 17
7007: Page 18
7100: Page 19
7120: Page 20
DRAWING 3
Page 5
Do not connect this fireplace to a
Fireplace
DON-BAR 7007
Combustible
Wall
24" min.
(610 mm)
Floor
Protection