Important Safety Information - Amana ALD10DT P1331001M Service Manual

Countertop commercial microwave ovens
Table of Contents

Advertisement

Important Safety Information

Read the following information to avoid possible exposure to microwave radiation:
The basic design of the Amana Microwave Oven makes it an inherently safe device to both use and service.
However, there are some precautions which should be followed when servicing the Radarange to maintain this
safety. These are as follows:
1. Always operate the unit from an adequately
grounded outlet. Do not operate on a two-wire
extension cord.
2. Before servicing the unit (if unit is operable)
perform the microwave leakage test.
3. The oven should never be operated if the door
does not fit properly against the seal, the hinges or
hinge bearings are damaged or broken, the choke
is damaged, (pieces missing, etc.), or any other
visible damage can be noted. Check the choke
area to ensure that this area is clean and free of
all foreign matter.
4. If the oven operates with the door open and
produces microwave energy, take the following
steps:
A. Tell the user not to operate the oven.
B. Contact Maytag Amana Manufacturing
immediately.
5. Always have the oven disconnected when the
outer case is removed except when making the
"live" tests called for in the Service Manual. Do
not reach into the equipment area while the unit is
energized. Make all connections for the test and
check them for tightness before plugging the cord
into the outlet.
6. Always ground the capacitors on the magnetron
filter box with an insulated-handle screwdriver
before working in the high voltage area of the
equipment compartment. Some types of failures
will leave a charge in these capacitors and the
discharge could cause a reflex action which could
make you injure yourself.
7. Always remember that in the area of the
transformer there is HIGH VOLTAGE. When the
unit is operating keep this area clear and free of
anything which could possibly cause an arc or
ground, etc.
4
!
WARNING
8. Do not for any reason defeat the interlock
switches. There is not valid reason for this action
at any time; nor will it be condoned by Amana.
9. IMPORTANT: Before returning a unit to a
customer, be sure to check for proper switch
interlock action.
10. Before returning a unit to a customer, be sure that
the door spacing is reasonably uniform along the
top, bottom, and sides, and that it measure
1/8" or less.
11. The Amana Microwave Oven should never be
operated with any components removed and/
or bypassed or when any of the safety interlocks
are found to be defective, or when any of the seal
surfaces are defective, missing, or damaged.
12. All Amana Microwave Ovens meet all
requirements of the radiation control for Health
and Safety Act of 1968. Due to measurement
uncertainties, the maximum leakage for the field
will be 4mw/cm
13. To ensure that the unit does not emit excessive
microwave leakage and to meet the Department
of Health and Human Services guidelines, check
the oven for microwave leakage using a leakage
monitor as outlined in the instruction. The
maximum leakage level allowed when following
those instructions is 4mw/cm
14. If servicer encounters an emission reading
over 4mw/cm
and contact the Amana Service Department
immediately for further direction. Amana
Manufacturing will contact the proper
Government Agency upon verification of the test
16400005
2.
.
2
, the servicer is to cease repair
2
©2009 ACP Inc.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ald10d p1331019mAld10t p1331002mAld 10d p1331011m

Table of Contents