PRESET PROGRAM TIMES AND TEMPERATURES

The programmer comes with preset Central Heating and Hot Water times and temperatures.
These can be amended using the appropriate procedures. The times can be deleted if they are not required (refer to Frame 8).
Central Heating Periods:
MON-FRI
Period 1 ON
Period 1 OFF
Period 2 ON
Period 2 OFF
Period 3 ON
Period 3 OFF
SAT-SUN
Period 1 ON
Period 1 OFF
Period 2 ON
Period 2 OFF
Period 3 ON
Period 3 OFF
Radiator Temperature
Hot Water Temperature:
7

FAULT FINDING

If the display shows a 'spanner' symbol, and the time or temperature indication is replaced by a 2-symbol Fault Code, then the
boiler is being prevented from running because of adverse conditions.
Those Codes beginning with 'H' are temporary and will reset when the fault condition has (been) cleared.
Those Codes beginning with 'L' are 'permanent', causing a 'Lockout' situation.
When one of these faults has been cleared, the boiler should be reset by pressing the 'Select' button for greater than 3
seconds.
The Select button is the equivalent of the small Reset button on boilers without programmers.
Further details of the Lockout Codes are in the main boiler instruction book, Fault Finding section.
ESPRIT 2 -
User's
Hot Water Periods:
MON-SUN
06:30
Period 1 ON
08:30
Period 1 OFF
17:00
Period 2 ON
22:30
Period 2 OFF
— : —
Period 3 ON
— : —
Period 3 OFF
07:30
10:00
12:00
14:00
17:00
22:30
82
o
C
o
60
C
06:30
00:00
— : —
— : —
— : —
— : —