6.24
WRITE AND VERIFY (2E H )
BIT
BYTE
7
6
5
4
3
2
1
0
00
--~---I--0---I--I---I--0---I--I---I-~-1--I---l--I---0--
01
Logical Unit Number
Reserved (0)
02
(MSB)
Loglcal Block Address
03
Logical Block Address
04
Logical Block Address
05
Logical Block Address
(LSS)
06
Reserved (0)
07
Number of Slocks
08
Number of Blocks
09
Reserved (0)
I
Flag
I
Link
Figure 6-40.
WRITE and VERIFY Command
This command is similar to the traditional "read after write"
function.
It is an extended address command which operates like
a WRITE command over the specified number of blocks and then
verifies the data written on a block by block basis. The verify
function transfers no data to the host and only checks the ECC to
be correct.
Since no data
is
transferred
to the host during verify,
correctable data checks will be treated in the same manner as
uncorrectable data checks.
Valid Error:
500504-00
Read Operation Errors
Write Operation Errors
ECC Error During Verify