Use this section as a guide when installing a generator set in a recreational vehicle, and then refer
to the appropriate operation section for specific instructions. When installing a RV generator set the
installation must comply with current standards of ANSI / RVIA EGS-1, ANSI A 119.2 / NFPA 501C,
and applicable articles of ANSI / NFPA 70 of the National Electrical Code. Generator set installations
must also comply with state and local requirements.
RV generator sets do not comply with United States Coast Guard (USCG) requirements and
must not be used for marine applications. Use only generator sets specified for marine use in marine
installations. USCG regulation 33CFR183 requires a generator set to be "ignition protected" when used
in a gasoline fueled environment.
This information section covers the RV generator set models listed below. To determine which
model is involved, check the model number found on the Power Technology nameplate attached to the
frame of the generator being installed. Follow all instructions to ensure proper installation and operation.
Each generator set features a Kubota diesel engine, rotating-field alternating current generator,
and a relay controller. The generator is directly connected to the engine for permanent alignment. Each
controller includes a Start / Stop switch for test operating the set at the controller. Also included is an On
/Off switch to reset the controller or lockout any remote switch to prevent starting while service is being
performed. The controller may be equipped with a switch to operate the mechanism used to move the
generator out of the coach for servicing. (Supplied by the coach manufacture). After the set is attached
to the frame of the vehicle, all that is usually required to make it operational is the following.
1. Attaching the exhaust system.
2. Add proper amount of radiator coolant.
3. Add oil to crankcase, to the dipstick FULL mark.
4. Connect fuel lines, remote switch, load leads and battery terminals.
(Consult the Specification Charts on the Following Pages for Requirements)
MODEL
GENERATOR DIMENSIONS L x W x H
WEIGHT
ENGINE
RPMs
KW RATING
AC VOLTAGE
AMPERAGE
Hz
PHASE
GENERATOR COMPARTMENT
FREE AIR OPENING
RADIATOR AIR REQUIREMENTS

GENERATOR INSTALLATION

in RECREATIONAL VEHICLES
INTRODUCTION
MARINE APPLICATION
GENERAL INFORMATION
PTSMH-15
46.5" x 23.0" x 32.0"
830
Kubota V-1903-BG
1800
15
120 / 240
125 / 63
60
1
400
Square Inches
2120 CFM
3
PTSMH-17.5
47.0" x 23.0" x 32.0"
840
Kubota V-2003-T
1800
17.5
120 / 240
146 / 73
60
1
400
Square Inches
2120 CFM
PTSMH-20
48.0" x 23.0" x 32.0"
850
Kubota V-2203-BG
1800
20
120 / 240
166 / 83
60
1
400
Square Inches
2120 CFM